HP31
Handbook
SL 3.0
Luminosity Controller
LUMINOSITY SETTING.
Press LUMIN (key lamp flashes):
This message will be displayed instead of the
Luminosity value (K.Lux).
Press + or - to modify. Press LUMIN to confirm.
MAIN SETTINGS (Run Mode)
Example with L.SEt = 50.0L
Attention: the reading of luminosity probe is only indicative.
Verify only with one precision luxometer the real reading of correspondence.
INSTALLATION
How to connect the line
Connect line on terminals L-N.
Protect supply with adequate fuse.
How to connect the contacts
Connect terminals on the terminal block (contacts up to 4AMP.AC1).
How to connect the sensor
Connect the provided sensor as shown in the diagram.
For remote connections use a standard 0.5-square millimeter two-pole wire , taking
great care over the connections, by insulating and sealing the joins carefully.
HP31
* Other power voltage if you required
230V LINE *
SHIELD CLOSING
LX LUMINOSITY
SENSOR
SHIELD OPENING
DAILY TIMER
N.O. CONTACT.
As it company policy to continually improve the products the Manufacturers
reserve the right to make any modifications thereto without prior notice. They
cannot be held liable for any damage due to malfunction.