Luminosity Controller
LUMINOSITY SETTING.
Press LUMIN (key lamp flashes):
This message will be displayed instead of the
Luminosity value (K.Lux).
Press + or - to modify. Press LUMIN to confirm.
MAIN SETTINGS (Run Mode)
Example with L.SEt = 50.0L
Attention: the reading of luminosity probe is only indicative.
Verify only with one precision luxometer the real reading of correspondence.
INSTALLATION
How to connect the line
Connect line on terminals L-N.
Protect supply with adequate fuse.
How to connect the contacts
Connect terminals on the terminal block (contacts up to 4AMP.AC1).
How to connect the sensor
Connect the provided sensor as shown in the diagram.
For remote connections use a standard 0.5-square millimeter two-pole wire , taking
great care over the connections, by insulating and sealing the joins carefully.
HP31
* Other power voltage if you required
230V LINE *
SHIELD CLOSING
LX LUMINOSITY
SENSOR
SHIELD OPENING
DAILY TIMER
N.O. CONTACT.
As it company policy to continually improve the products the Manufacturers
reserve the right to make any modifications thereto without prior notice. They
cannot be held liable for any damage due to malfunction.
21.12.12
This processor is already programmed with the following (variable) settings.
To return to these settings at any time you may:
Power off the processor, press LUMIN key and keep it pressed giving power on:
boot message will be displayed (release now LUMIN key).
L.SEt = 50.L.
The COSt values are shown in COSt Programming
PRESET PROGRAMS (Bootstrap)
These settings refer to the operation mode of the system and must be made on
initial startup. Press - / + at the same time for at least one second: the message
C.O.S.t. will be displayed.
Press than repeatedly LIMIN until the message regarding the chosen variable
is displayed (see table below) : value of variable and message will be displayed.
Press + or - to set a new value and then press LUMIN to confirm.
The next system constant will then appear.
You can press LUMIN for at least 2 seconds to exit and return to the Run Mode.
COSt PROGRAMMING (System constants)
*1) For more details see Operative Diagram.
*2) You can correct the readings on the various sensors (+ or -).
.sseM eulaV gninaeM etoN
b.n
L0.5
egnarlartuen%
)1*
OLC.b
L0.0
dnabnoitaludomdesolc%
)1*
EPO.b
L0.05
dnabnoitaludomnepo%
)1*
no.t
"0.1
sdnocesniemitno
)1*
Fo.t
"9.99
sdnocesniemitffo
)1*
UL.dA
n00.1
eborpytisonimul)tneiciffeoc(rotcafevitacipiltlumnoitcerroC
)2*
OPERATIVE DIAGRAM
t.On t.oF t.On t.On t.oF t.On
L.SEt
ON OPEN ON CLOSED
1/2 nb 1/2 nb
b.OPE b.CLOn.b.
ON ON ON ONOFF OFF OFF
The lights situated at the bottom of the display show the state of the various relays as set out below.
STATE INDICATION LAMPS
closed action state
open action state
ON CLOSINGON OPENING
Day condition On:
opening and closing regulation with
luminosity controller.
Night condition On:
completely closed
VIEWING AMBIENT TEMPERATURE RECORDING
Values are permanently stored in the memory: for deleting all values in the memory keep
pushed + key for more than 3 seconds: CLEA message will appear on display before
clearing operation.
Press - : will be displayed followed by
°Minimum Temperature Recording.
Press + : will be displayed followed by
°Maximum Temperature Recording.
In some start-up conditions may be useful to work in "manual" mode:
Power off the processor, press + key and keep it pressed giving power on: HAnd
message will be displayed (release now + key).
Press + (1 is displayed) and press LUMIN to activate relay.
You can press LUMIN key for a least two seconds to escape and return to the
Run Mode.