15
Operation
PARTS MANUALS AVAILABLE ONLINE AT smithco.com
OPERATION (CONTINUED)
SPRAYER VALVE SETTINGS AND SPRAY TANK AGITATION
The 3-way valve on the suction side of the pump, between the tank and the pump must be open before pump is
engaged. Close this valve only when necessary to clean the filter with spray material in the spray tank.
There is one manual flow control valve on the discharge side of the spray system. This valve controls the agita-
tor. This valve may be opened as much as necessary to provide hydraulic agitation through the quadrajet agitator
in the tank bottom. This valve may be partially closed to prevent or reduce foam buildup from the spray materials
inside the tank. When the liquid level in the spray tank reaches a certain level (usually 1-25 gallons (3.8-95 Li-
ters) depending on terrain and other conditions) it may be necessary to close the valve in the agitator line in
order to prevent loss of suction prime.
If your Spray Star is fitted with a hose reel, there is a second ball valve on the discharge system to supply mate-
rial to the hose reel.
The Quadrajet agitation system operates with four venturi jets in the tank bottom. These jets have replaceable
orifice discs which discharge the following amounts of spay material.
Input to Input to Agitator Agitator Agitator Agitator
Nozzle Agitator Agitator Pressure Pressure Output Output
Diameter in gpm in L/min in psi in bar in gpm in L/min
1
/8" 1.9 7.2 25 1.7 6.3 23.8
1
/8" 2.7 10.2 50 3.4 10.0 37.9
1
/8" 3.8 14.4 100 6.9 15.0 56.8
5
/32" 2.8 10.6 25 1.7 7.6 28.8
5
/32" 4.2 15.9 50 3.4 12.2 46.2
5
/32" 5.5 20.8 100 6.9 17.5 66.2
3
/16" 3.6 13.6 25 1.7 9.1 34.4
3
/16" 5.6 21.2 50 33.4 14.3 54.1
3
/16" 7.9 29.9 100 6.9 18.7 70.8
You can change orifice disc sizes to enhance spray system performance. Smaller discs reduce amount of agita-
tion (desirable in some foaming materials) and make more dischargeable liquid available for nozzles. Larger (or
none) discs increase amount of agitation and make less dischargeable liquid available for nozzles.
ENVIZIO PRO II DO'S AND DON'TS
DO’S AND DON’TS
Do have the serial number and firmware revision available when calling for technical assistance. It is best if
the user is in the machine and in front of the field computer when calling for support.
Do review the manual in its entirety before operating the field computer.
Do turn machine on prior to starting Envizio Pro II. Voltage spikes can cause damage to computer.
Don't let water on or near Envizio Pro II Computer.
Don’t turn the field computer off without properly closing any open jobs and powering down the computer. If
the field computer loses power during a job, information within the job files may be lost and the associated
files may become corrupt.
Do power down Envizio prior to shutting off machine.
Don’t use sharp objects or harsh chemicals on the field computer touch screen as they may damage the
display. Console Features
Do remove Envizio Pro II during cold weather. Cold weather will cause the battery to drain.
Envizio Pro II comes with a Quick Reference Guide and an Installation & Operation Manual. Please read
these manuals before operation. Manuals can be downloaded off the internet at www.ravenprecision.com
and off the www.smithco.com website under Parts and Technical Information.