Woods AC CAPRI Silent 9K Operating Instructions Manual

Tüüp
Operating Instructions Manual

See käsiraamat sobib ka

AIR CONDITIONER
Revision date: 2020-02-05AC Capri Silent 9K
Visit woods.se for more information and updated instruction manuals.
For extended warranty register your product at warranty-woods.com
OPERATING INSTRUCTIONS FOR:
Operating Instructions
GB
Betjeningsvejledning
DK
Manual de instrucciones
ES
Lietošanas instrukcija
LV
Bedienungsanleitung
DE
Instrukcja obsługi
PL
Bruksanvisning
SE
Guide dinstructions
FR
yttöohjeet
FI
Naudojimosi instrukcija
LT
Kasutusjuhend
EE
Gebruiksaanwijzing
NL
Manual utilizare
RO
Bruksanvisning
NO
Greek
GK
Icelandic
IS
AC CAPRI Silent 9K WAC901G
GB
2
Operating Instructions
Visit our website to:
Get usage advice, updated brochures, troubleshoot and
service information
Register your product for additional services:
www.warranty-woods.com
CUSTOMER CARE AND SERVICE
Always use original spare parts.
When contacting our Authorised Service Centre,
ensure that you have the following data available:
Model number, receipt and serial number.
The refrigerant used in portable air conditioner is
the environmentally friendly hydrocarbon R290. This
refrigerant is odorless, and compared to the alternative
refrigerant, the R290 is an ozone-free refrigerant.
Warning / Caution-Safety information.
General information and tips.
Environmental information.
Subject to change without notice.
GB
3
Operating Instructions
CONTENTS: PAGE NO.
TABLE OF CONTENTS
OPERATING INSTRUCTIONS
English
Swedish
Norwegian
Danish
German
French
Spanish
Dutch
Polish
Romanian
Finnish
Lithuanian
Latvian
Estonian
Greek
Icelancic
12-19
20-27
28-35
36-43
44-51
52-59
60-67
68-75
76-83
84-91
92-99
100-107
10 8 -115
116 -123
124-131
132-139
Table of Contents
GB
4
Operating Instructions
1
A.
4
7
2
5
3
6
B.
GB
5
Operating Instructions
D.
C.
PRODUCT DESCRIPTION
GB
6
Operating Instructions
E.
PRODUCT DESCRIPTION
F.
GB
7
Operating Instructions
H.
G.
PRODUCT DESCRIPTION
GB
8
Operating Instructions
PRODUCT DESCRIPTION
I.
J.
L.
GB
9
Operating Instructions
PRODUCT DESCRIPTION
K.
L.
GB
10
Operating Instructions
M.
N.
P.
GB
11
Operating Instructions
O.
P.
GB
12
Operating Instructions
WOOD’S FOR CLEAN AND HEALTHY
INDOOR AIR
The brand Wood’s was born with the
Wood’s family over 65 years ago in the
Canadian city of Guelph, Ontario. This
is where Wood’s began developing and
manufactoring dehumidifie s in 1950. Since
then Wood’s has helped several hundred
thousand households to prevent damages
from mould damp, and to breathe
cleaner air. Our portable air conditioners
are suitable for use in most climates,
where capacity is good even at dierent
temperatures and humidity levels. They
are used with good results in premises that
become hot such as livingrooms, oces
or bedrooms. The amount of hot air that
the air conditioner removes depends
on the temperature, humidity level and
placement. External weather conditions
may also aect the performance of the air
conditioner.
Wood’s air conditioners are safe in
operation and intended for continuous use
over many years.
HOW DOES THE AIR CONDITIONING
UNIT WORK?
Low pressure gives cold air
The main element of the air conditioner
is a coolant, which under low pressure is
converted to gas. The process “creates
cold”, which is transmitted inward, while
keeping the warm air out.
A liquid coolant is passed through an
expansion valve and into a pipe where the
pressure is low.
The coolant evaporates and turns into a
gas. The process absorbs heat from the
surroundings and the pipe is cooled.
A fan blows the cold air into the room.
The gas is passed through a compressor,
which increases the pressure and converts
the gas into liquid.
In this process, heat is released, which
is led to pipes on the opposite side and
blown out by a fan.
A thermostat shuts off he unit when the
indoor air is cold enough.
1. SECURITY WARNINGS
Flammable material. This
appliance contains R290/
Propane a ammable refrigerant.
Refer to this manual for
safety information.
Read technical manual
Read operators manual.
SAFETY INFORMATION
Before the installation and use
of the appliance, carefully read
the supplied instructions. The
manufacturer is not responsible
if an incorrect installation and
use causes injuries and damages.
Always keep the instructions with
the appliance for future reference.
Children and vulnerable people
safety
WARNING
Risk of injury or permanent
disability.
This appliance can be used by
children aged 8 years and above
and persons with reduced physical,
sensory or mental capabilities or
lack of experience and knowledge
if they have been given supervision
or instruction concerning use of
the appliance in a safe way and
understand the hazards involved.
Do not let children play with the
appliance.
Children of less than 3 years should
be kept away unless continuously
supervised.
Keep all packaging away from
children.
Cleaning and user maintenance
shall not be made by children
without supervision.
General Safety
This appliance is intended to be
used in household and similar
applications such as: Family room,
living room, staff itchen areas in
shops, oces and other working
environments. The rating plate is
located at the side or back of the
Air Conditioner.
Keep ventilation openings clear of
obstruction.
Do not use mechanical devices
or other means to accelerate the
defrosting process, other than
those recommended by the
manufacturer.
The appliance shall not be stored
in a room with operating ignition
sources (for example: open ames,
an operating gas appliance or an
operation electric heater. Do not
pierce or burn.
Be aware that refrigerants may
not contain an odour. Do not use
water spray and steam to clean the
appliance. Clean the appliance with
a moist soft cloth. Only use neutral
detergents. Do not use abrasive
products, abrasive cleaning pads,
solvents or metal objects.
If the supply cord is damaged,
it must be replaced by the
manufacturer, its Authorised
Service Centre or similarly qualied
persons in order to avoid a hazard.
SAFETY INSTRUCTIONS
Installation
WARNING
Only a qualied person must install
this appliance.
Remove all the packaging.
Do not install or use a damaged
appliance. The appliance shall be
installed, operated and stored in
a room with a oor area larger
than 4 m². Obey the installation
instruction supplied with the
appliance.
Always be careful when you move
the appliance because it is heavy.
Always wear safety gloves. Be
aware that refrigerants may not
contain an odour.
Make sure the air can circulate
around the appliance.
Wait at least 4 hours before
connecting the appliance to the
power supply. This is to allow the
oil to ow back in the compressor.
Do not install the appliance close
to radiators or other heat sources.
Do not install the appliance where
there is direct sunlight.
Electrical connection
WARNING
Risk of re and electrical shock.
The appliance must be connected
to a grounded outlet.
Make sure that the electrical
information on the rating plate
matcheswith the power supply. If
not, contact an electrician.
GB
13
Operating Instructions
Do not let children play with the
appliance.
Children of less than 3 years should
be kept away unless continuously
supervised.
Keep all packaging away from
children.
Cleaning and user maintenance
shall not be made by children
without supervision.
General Safety
This appliance is intended to be
used in household and similar
applications such as: Family room,
living room, staff itchen areas in
shops, oces and other working
environments. The rating plate is
located at the side or back of the
Air Conditioner.
Keep ventilation openings clear of
obstruction.
Do not use mechanical devices
or other means to accelerate the
defrosting process, other than
those recommended by the
manufacturer.
The appliance shall not be stored
in a room with operating ignition
sources (for example: open ames,
an operating gas appliance or an
operation electric heater. Do not
pierce or burn.
Be aware that refrigerants may
not contain an odour. Do not use
water spray and steam to clean the
appliance. Clean the appliance with
a moist soft cloth. Only use neutral
detergents. Do not use abrasive
products, abrasive cleaning pads,
solvents or metal objects.
If the supply cord is damaged,
it must be replaced by the
manufacturer, its Authorised
Service Centre or similarly qualied
persons in order to avoid a hazard.
SAFETY INSTRUCTIONS
Installation
WARNING
Only a qualied person must install
this appliance.
Remove all the packaging.
Do not install or use a damaged
appliance. The appliance shall be
installed, operated and stored in
a room with a oor area larger
than 4 m². Obey the installation
instruction supplied with the
appliance.
Always be careful when you move
the appliance because it is heavy.
Always wear safety gloves. Be
aware that refrigerants may not
contain an odour.
Make sure the air can circulate
around the appliance.
Wait at least 4 hours before
connecting the appliance to the
power supply. This is to allow the
oil to ow back in the compressor.
Do not install the appliance close
to radiators or other heat sources.
Do not install the appliance where
there is direct sunlight.
Electrical connection
WARNING
Risk of re and electrical shock.
The appliance must be connected
to a grounded outlet.
Make sure that the electrical
information on the rating plate
matcheswith the power supply. If
not, contact an electrician.
Always use a correctly installed
shockproof socket.
Do not use multi-plug adapters
and extension cables.
Make sure not to cause damage
to the electrical components (e.g.
mains plug, mains cable).
Contact the Authorised Service
Centre or an electrician to change
the electrical components.
The mains cable must stay below
the level of the mains plug.
Connect the mains plug to the
mains socket only at the end of the
installation.
Make sure that there is access
to the mains plug after the
installation.
Do not pull the mains cable to
disconnect the appliance. Always
pull at the mains plug.
Use
WARNING
Risk of injury, burns, electrical
shock or re.
Do not change the specication of
this appliance.
Be careful not to cause damage to
the refrigerant circuit. It contains
propane (R290), a natural gas with
a high level of environmental
compatibility. This gas is
ammable.
If damage occurs to the refrigerant
circuit, make sure that there are no
ames and sources of ignition in
the room. Ventilate the room.
Do not put ammable products or
items that are wet with ammable
products near or on the appliance.
Disposal
WARNING
Risk of injury.
Disconnect the appliance from the
mains supply.
Cut off he mains cable and discard
it.
The refrigerant circuit of this
appliance is ozone-friendly.
Contact your municipal authority
for information on how to discard
the appliance correctly.
Do not cause damage to the part
of the cooling unit that is near the
heat exchanger.
GB
14
Operating Instructions
2. Installation
Important
1. This air conditioner may be moved around indoor
conveniently; keep the unit in upright position while
moving it. The air-conditioner shall be placed at a at
surface.
Do not install or operate this air-conditioner in a bathroom
or other wet environment.
Since a portable air conditioner is on wheels, it is easy
to change positions. When the heat turns on, you just
move your portable air conditioner into the room and can
quickly get started cooling the space.
Air conditioner must be operated in an
enclosed area to be most eective.
Close all doors, windows, and other
outside openings to the room. The
eectiveness of the Air Conditioner
depends on the temperature and humidity level.
2. Place the air conditioner in a location that
does not restrict airow through the
front of the unit.
3. An Air Conditioner operating in a
room will have little or no eect
in drying an adjacent enclosed storage
area, such as a closet, unless there
is adequate circulation of air in and
out of the area. A portable Air Conditioner evacuates
the heat from the unit with a ventilation hose through a
window or exhaust air valve.
4. There should be a minimum of
30 cm distance between Air Conditioner and closest
object. See picture for reference.
SET UP AIR CONDITIONER FOR INSTALLATION
GB
15
Operating Instructions
3. Product description
A
1. Exhaust hose
2. Hose adapter
3. Window Kit adapter
4. Window Kit
5. Do
wel
6. Batteries
7. Remote Controller
C
1. Control panel
2. Front cover
3. Louver
4. Castor
5. Power cord
6. Drainage outlet
7. Air inlet
8. Air outlet
9. Air inlet
B
1. Product pictures
D
1. Product back pictures
F
1. Water full
2. High fan speed
3. Low fan speed button
4. TIMER
5. Cooling button
6. Dehumidifying button
7. Fan
F
A. Power on/o
B. Temperature up
C. Temperature down
D. Operation MODE
E. Fan speed
F. Timer on/o
G
1. Picture of air filter unloading
H
1. Schematic diagram of filter
cleaning
K
Twist the hose adaptor and the
window Connector to the ends of the
exhaust hose.
L
1. Introduction to Exhaust Hose Installation
M
1. Window Slider Kit Installation
N
1. Insert the window connector of the hose
PRODUCT DESCRIPTION
E
1. Product top picture
I
1. Power on/o
2. Timer on/o
3. Operation MODE
4. Fan speed
5. Temperature up
6. Temperature down
J
1. Remote control batteries
installation
1.
to the hole of the window kit
O
1. Connect drain hose
P
1. Picture of water outlet
GB
16
Operating Instructions
A. Accessories
After unpacking, please check whether
the above-mentioned accessories are
included, and check their purposes in
the installation introduction in this
manual.
B. Mobile air conditioner
J. Appearance and Function of Remote
Control.
Notes:- Do not drop the remote control.-
Do not place the remote control in a
location exposed to direct sunlight.
M. Operation Introduction
Before starting operations in this section:
1) Find a place where there is power
supply nearby.
2) Install the exhaust hose, and adjust
the window position well.
3) Connect drain hose well (only for using
heating model);
4) Insert the power cord into an grounded
AC220~240V/50Hz socket;
5) Press the POWER button to turn on
the air-conditioner.
K&L. Introduction to Exhaust Hose
Installation
A) Temporary installation
1.Twist both ends of the exhaust hose
into the Hose Connector.
2.Insert the square xing clip into air
outlet at back of the air conditioner
3.Put the other end of the exhaust hose
to the near windowsill.
N. Window Slider Kit Installation
The installation manner of window slider
kit is mostly in “horizontal” and
“vertical. As shown Fig.5 and Fig.5a,
check the min. and max. size of the
window before the installation.
1. Install the window kit on the window ;
2. Adjust the length of the window slider
kit according to the window width or
height, and x it with the dowel;
3. Insert the Window Connector hose to
the hole of the Window Kit.
O. Internal Tank Water Full Alarm
Function
The inner water tank in the airconditioner
has one water level safety
switches, it controls water level. When
water level reaches an anticipated
height, the water full indicator lamp
lights up. (If water pump is damaged,
when the water is full, please remove
the rubber blockage at the bottom of
unit, and all water will be drained
outside.)
H. Maintenance Explanations
Declaration:
1) Before cleaning, be sure to
disconnect the unit from any electric
supply outlet;
2) Do not use gasoline or other
chemicals to clean the unit;
3) Do not wash the unit directly;
4) If the conditioner is damaged,
please contact the dealer or repair
shop.
1. Air Filter
-If the air lter becomes clogged with
dust/dirt, the air lter should be
cleaned once every two weeks.
-Dismounting
Open the air inlet grille and take off ir
lter.
-Cleaning
Clean the air lter with neural
detergent in lukewarm ( 40°C ) and
dry it up in the shade.
-Mounting
Putting the air lter into the inlet grille,
replace the components as they were.
2. Clean the Air-conditioner Surface
First clean the surface with a neutral
detergent and wet cloth, and then
wipe it with a dry cloth.
E. Before using
Check up whether the exhaust hose
has been mounted properly.
Cautions for cooling and
dehumidifying operations:
-When using functions on cooling and
dehumidifying, keep an interval of at
least 3 minutes between each
POWER.
-Power supply meets the
requirements.
-The socket is for AC use.
-Do not share one socket with other
appliances.
-Power supply is
AC220-240V, 50Hz
2. Cooling operation
-Press the “Mode” button till the
“Cool” icon appears.
-Press the “ ”or“ ”button to select
a desired room temperature.
(16°C -31°C )
-Press the “Fan Speed” button to
select wind speed.
3. Dehumidifying operation
Press the “Mode” button till the
“Dehumidify” icon appears .
-Automatically set the selected
temperature to current room
temperature minus 2°C .
-Automatically set the fan motor to
LOW wind speed.
4. Fan operation
-Press the “Mode” button till the “Fan”
icon appears.
-Press the “Fan Speed” button to
select wind speed.
5. Heating operation (this function is
not available for a cold-single unit)
-Press the “Mode” button till the
“Heat” icon appears.
-Press the “ ”or“ ” button to select
a desired room temperature.
(16°C-31°C)
-Press the “Fan Speed” button to
select wind speed.
FUNCTION OF THE OPERATION MODES AND INSTALLATION DESCRIPTIONS
It is very important that the lter
is cleaned regularly; otherwise
the air conditioner might lose
capacity and even be seriously
damaged.
GB
17
Operating Instructions
E. Before using
Check up whether the exhaust hose
has been mounted properly.
Cautions for cooling and
dehumidifying operations:
-When using functions on cooling and
dehumidifying, keep an interval of at
least 3 minutes between each
POWER.
-Power supply meets the
requirements.
-The socket is for AC use.
-Do not share one socket with other
appliances.
-Power supply is
AC220-240V, 50Hz
2. Cooling operation
-Press the “Mode” button till the
“Cool” icon appears.
-Press the “ ”or“ ”button to select
a desired room temperature.
(16°C -31°C )
-Press the “Fan Speed” button to
select wind speed.
3. Dehumidifying operation
Press the “Mode” button till the
“Dehumidify” icon appears .
-Automatically set the selected
temperature to current room
temperature minus 2°C .
-Automatically set the fan motor to
LOW wind speed.
4. Fan operation
-Press the “Mode” button till the “Fan”
icon appears.
-Press the “Fan Speed” button to
select wind speed.
5. Heating operation (this function is
not available for a cold-single unit)
-Press the “Mode” button till the
“Heat” icon appears.
-Press the “ ”or“ ” button to select
a desired room temperature.
(16°C-31°C)
-Press the “Fan Speed” button to
select wind speed.
6. Timer operation
Timer ON setting:
-When the air-conditioner is OFF,
press the “Timer” button and select a
desired ON time through the
temperature and time setting buttons.
-“Preset ON Time” is displayed on the
operation panel.
-ON time can be regulated at any time
in 0-24 hours.
Timer OFF setting
-When the air-conditioner ON, press
Timer” button and select a desired
OFF time through the temperature
and time setting buttons.
-“Preset OFF Time” is displayed on
the operation panel.
-OFF time can be regulated at any
time in 0-24 hours.
7. Continuous Drainage
Internal Tank Water Full Alarm
Function
The inner water tank in the airconditioner
has one water level safety
switches, it controls the water level.
When water level reaches an
anticipated height, the water full
indicator lights up. When the water is
full, please remove the rubber
blockage from the drainage hole at
the bottom of unit, and drain all water
outside.
Continuous Drainage
-When you plan to leave this unit
unused for a long time, please
remove the rubber blockage from the
drainage hole at the bottom of unit,
and drain all water outside.
-You can use the continuous drainage
with a drainage hose connected to the
bottom drain hole, when the unit
working at the HEAT mode.
-The continuous drainage is not need
to be applied when the unit working at
the COOL or DEHUMIDIFY mode.
The unit can evaporate the
condensate water automatically by
the splash motor. Make sure the
drainage holes are stemmed well.
-If water splash motor is damaged,
continuous drainage can be used.
To connect the drain hose to the
bottom drain hole, the unit can also
work well.
-If splash motor is damaged,
intermittent drainage can also be
used. Under this condition, when the
water full indicator lights up, please
connect a drain hose to the bottom
drainage hole, then all the water in the
water tank will be drained outside. The
unit can also work well.
8. WIFI function
- Long press the SPEED button for
5s, enter the WIFI factory set up
mode;
- The unit is connected with WIFI If
the WIFI indicator is on, other wise is
not connected. When the WIFI
indicator ashing slowly, the unit is at
the WIFI set up mode, if ashing
quickly, the unit is connected with
WIFI;
- You can realize all the air
conditioner functions by the mobile
phone APP with the WIFI connected.
Maintenance
Clean the condensor with Wood’s
cleaning
detergent. Read more about how
to clean your unit at woods.se Clean the
unit with a soft moist cloth. Do not use
solvents or strong cleaners as this might
damage the surface of the unit.
Service
If the Air Conditioner requires servicing,
you must rst contact your local retailer.
Proof of purchase is required for all
warranty claims.
Storage instructions
End of Season Storage
1) Screw off he drain cover and pull out
the stopper to drain condensate water
completely.
2) Keep unit running in fan mode for half
day to dry inside of unit completely to
prevent from going moldy.
3) Turn off he unit, pull out plug then
wrap the power cord around the wire-
winding pillar, insert the plug into the
universal xing hole at the back panel
of the unit, install the water stopper and
drain cover.
4) Remove the heat exhaust hose
assembly,
clean and keep it properly.
Notes:
Hold the exhaust hose assembly with
both hands when removal.
Push the fasteners aside on exhaust air
outlet using your thumbs, then pull out
exhaust hose assembly.
5) Pack the air-conditioner properly with
soft plastic bag and put it in dry place
with appropriate dust-proof measures,
and keep the unit away from children.
6) Take out the batteries from the remote
control and keep it properly.
Note:
Assure the unit is stored in a dry place.
All accessories of the unit shall be
protected
together properly
Power cord holder and universal socket
can well protect the power cord.
High position of exhaust air outlet, easy
assembly and venting quickly.
Intelligent, environmental-friendly and
energy saving with self-evaporative
cooling system.
24-hour Timer function, unique on/o
reminding music.
3-minute delay re-starting protection to
compressor and other multiple protection
functions.
FUNCTION OF THE OPERATION MODES AND INSTALLATION DESCRIPTIONS
FUNCTION OF THE OPERATION MODES AND INSTALLATION DESCRIPTIONS
GB
18
Operating Instructions
PROBLEM CAUSE REMEDY
Unit does not start
when pressing on/o
button
Water full indicator lamp blinks and water tank is full. Dump the water out of the water tank.
Room temperature is higher than the setting temperature
(Electric heating mode)
Reset the temperature
Room temperature is lower than the setting temperature.
(Cooling mode)
Reset the temperature
Not cool enough
The doors or windows are not closed. Make sure all the windows and doors are closed.
There are heat sources inside the room. Remove the heat sources if possible
Exhaust air hose is not connected or blocked. Connect or clean the exhaust air hose.
Temperature setting is too high. Reset the temperature
Air inlet is blocked. Clean the air inlet.
High noise level
The ground is not level or not at enough Place the unit on a at, level ground if possible
The sound comes from the owing of the refrigerant inside the
air conditioner
It is normal.
If you are having trouble with your dehumidier, please refer to below trouble shooting. If nothing of the below
works, please contact your retailer for servicing of your Air Conditioner.
Error Codes CAUSE REMEDY
E0 Code
Room temperature sensor failed
Replace room temperature sensor (the unit can also work
without replacement.)
E1 Code
Condenser temperature sensor failed Replace condenser temperature sensor
E2 Code
Water tank full when cooling Take off ubber stopper and empty the water.
E3 Code
Evaporator temperature sensor failed Replace evaporator temperature sensor
E4 Code
Water tank full when heating Please empty the water tank.
GB
19
Operating Instructions
PROBLEM CAUSE REMEDY
Unit does not start
when pressing on/o
button
Water full indicator lamp blinks and water tank is full. Dump the water out of the water tank.
Room temperature is higher than the setting temperature
(Electric heating mode)
Reset the temperature
Room temperature is lower than the setting temperature.
(Cooling mode)
Reset the temperature
Not cool enough
The doors or windows are not closed. Make sure all the windows and doors are closed.
There are heat sources inside the room. Remove the heat sources if possible
Exhaust air hose is not connected or blocked. Connect or clean the exhaust air hose.
Temperature setting is too high. Reset the temperature
Air inlet is blocked. Clean the air inlet.
High noise level
The ground is not level or not at enough Place the unit on a at, level ground if possible
The sound comes from the owing of the refrigerant inside the
air conditioner
It is normal.
If you are having trouble with your dehumidier, please refer to below trouble shooting. If nothing of the below
works, please contact your retailer for servicing of your Air Conditioner.
Error Codes CAUSE REMEDY
E0 Code
Room temperature sensor failed
Replace room temperature sensor (the unit can also work
without replacement.)
E1 Code
Condenser temperature sensor failed Replace condenser temperature sensor
E2 Code
Water tank full when cooling Take off ubber stopper and empty the water.
E3 Code
Evaporator temperature sensor failed Replace evaporator temperature sensor
E4 Code
Water tank full when heating Please empty the water tank.
*This marking indicates that this product should not be disposed with other household wastes throughout the EU. To prevent possible harm
to the environment or human health from uncontrolled waste disposal, recycle it responsibly to promote the sustainable reuse of material
resources. To return your us device, please use the return and collection systems or contact the retailer where the product was purchased.
They can take this product for environmental safe recycling.
NOTE!
Register at www.warranty-woods.com
and read about how to get
extended warranty. Please visit
www.woods.se for more information.
Recommended limits for use
The best operating ambient temperature
for cooling is 18-35 °C,
and the optimum ambient temperature
for heating is 8-25 °C. The unit runs up
to +45°C .Fuse Parameter: φ5.0x20mm
3.15A, 250Vac.
AC Capri Silent 9K
Cooling capacity 2,6W
Power consumption 1,0KW
Air flow: 320m³ / h
Energy class A
Dehumidification 24 L / 24h
Temperature setting 16-31°C
Working temperatur 18-35°C
EER 2,6
Refrigerant gas R290/160g
Noise level in decibels 65dB
Weight
19kg/20.5kg
D
imensions in mm, L x Bx H 330x280x680
TECHNICAL DATA
*Technical changes and improvements may occur. All values are approximate and may vary due to external circumstances such as
temperature, ventilation and humidity.
NOTE!
Register at www.warranty-woods.com
and read about how to get extended
warranty. Please visit www.woods.se for
more information.
Guarantees
2 years consumer warranty against production faults. Please note that the warranty is only valid upon
the production of the receipt. The warranty is only valid if the product is used in accordance with
the instructions and security warnings expressed in this manual. The warranty does not cover any
damages caused by improper handling of the product.
NOTE: The 2 years warranty only applies for consumers and not for
commercial use of the unit.
SE
20
Bruksanvisning
WOOD’S FÖR REN OCH HÄLSOSAM
INOMHUSLUFT
Varumärket Wood’s grundades av
familjen Wood för mer än 65 år sedan
i den kanadensiska staden Guelph,
Ontario. Det var då, på 1950-talet, som
Wood’s började utveckla och tillverka
avfuktare. Sedan dess har Wood’s hjälpt
hundratusentals hushåll med att förhindra
skador orsakade av mögel till följd av
ånga, och att luften de andas är renare.
Våra portabla luftkonditioneringsaggregat
lämpar sig för användning i de esta
klimat, där kapaciteten är bra även när
temperaturen och luftfuktigheten varierar.
De används med gott resultat i lokaler
som blir varma, såsom vardagsrum, kontor
eller sovrum. Mängden varm luft som
luftkonditioneringsaggregatet avlägsnar
beror på temperaturen, luftfuktigheten
och aggregatets placering. Yttre
väderförhållanden kan också påverka
luftkonditioneringens prestanda.
Wood’s luftkonditioneringar är säkra att
använda och avsedda för kontinuerlig
användning under många år.
HUR FUNGERAR
LUFTKONDITIONERINGSENHETEN?
Lågt tryck ger kall luft
Den viktigaste komponenten i ett
luftkonditioneringsaggregat är
köldmediet, som under lågt tryck
omvandlas till gas. Processen ”skapar kyla”
som överförs inåt, medan den varma luften
stängs ute.
Ett ytande köldmedium passerar genom
expansionsventilen och in i ett rör där
trycket är lågt.
Köldmediet förångas och förvandlas till
gas. Processen absorberar värme från
omgivningen och röret kyls.
En äkt blåser den kalla luften in i rummet.
Gasen leds genom en kompressor som
ökar trycket och omvandlar gasen till
vätska.
I den här processen frigörs värme, som leds
i rör på motsatt sida och blåses ut av en
äkt.
En termostat stänger av enheten när
inomhusluften är tillräckligt kall.
1. SÄKERHETSVARNINGAR
Brandfarligt material. Denna
apparat innehåller R290/ propan,
ett brandfarligt köldmedium.
Se denna bruksanvisning för
säkerhetsinformation.
Läs den tekniska manualen
Läs bruksanvisningen.
KERHETSINFORMATION
Läs igenom de medföljande
instruktionerna noggrant före
installation och användning av
apparaten. Tillverkaren tar inget
ansvar för felaktig installation
som orsakar personskador och
materiella skador. Förvara alltid
instruktionerna tillsammans med
apparaten för framtida referens.
Barn och utsatta personers
kerhet
VARNING
Risk för personskada eller
permanent invaliditet.
Denna apparat kan användas
av barn från 8 år och uppåt och
personer med nedsatt fysisk,
sensorisk eller mental förmåga
eller bristande erfarenhet och
kunskap om de har fått tillsyn eller
instruktioner om användning av
apparaten på ett säkert sätt och
förstå de faror som är inblandade.
Låt inte barn leka med apparaten.
Barn som är yngre än 3 år bör
llas borta om de inte övervakas
kontinuerligt.
Förvara allt emballage utom
räckhåll för barn.
Rengöring och underhåll får inte
göras av barn utan uppsikt.
Allmän säkerhet
Denna apparat är avsedd att
användas i hushåll och liknande
tillämpningar såsom: familjerum,
vardagsrum, personalkök
i butiker, kontor och andra
arbetsmiljöer. Märkskylten är
placerad på sidan eller baksidan av
luftkonditioneringen.
Se till att ventilationsöppningarna
inte är blockerade.
Använd inte mekaniska
anordningar eller andra hjälpmedel
för att påskynda avfrostningen
än de som rekommenderas av
tillverkaren.
Apparaten får inte förvaras i ett
rum med antändningskällor som
är aktiva (till exempel: öppen
eld, gasdriven utrustning eller
en elektrisk värmare. Får inte
punkteras eller brännas.
nk på att köldmedier kan avge
lukt. Använd inte vattenspray och
ånga för att rengöra apparaten.
Rengör apparaten med en fuktig,
mjuk trasa. Använd endast neutrala
rengöringsmedel. Använd inte
slipmedel, den slipande sidan på
kökssvampar, lösningsmedel eller
metallföremål.
Om nätsladden är skadad måste
den bytas ut av tillverkaren, dess
auktoriserade servicecenter eller
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72
  • Page 73 73
  • Page 74 74
  • Page 75 75
  • Page 76 76
  • Page 77 77
  • Page 78 78
  • Page 79 79
  • Page 80 80
  • Page 81 81
  • Page 82 82
  • Page 83 83
  • Page 84 84
  • Page 85 85
  • Page 86 86
  • Page 87 87
  • Page 88 88
  • Page 89 89
  • Page 90 90
  • Page 91 91
  • Page 92 92
  • Page 93 93
  • Page 94 94
  • Page 95 95
  • Page 96 96
  • Page 97 97
  • Page 98 98
  • Page 99 99
  • Page 100 100
  • Page 101 101
  • Page 102 102
  • Page 103 103
  • Page 104 104
  • Page 105 105
  • Page 106 106
  • Page 107 107
  • Page 108 108
  • Page 109 109
  • Page 110 110
  • Page 111 111
  • Page 112 112
  • Page 113 113
  • Page 114 114
  • Page 115 115
  • Page 116 116
  • Page 117 117
  • Page 118 118
  • Page 119 119
  • Page 120 120
  • Page 121 121
  • Page 122 122
  • Page 123 123
  • Page 124 124
  • Page 125 125
  • Page 126 126
  • Page 127 127
  • Page 128 128
  • Page 129 129
  • Page 130 130
  • Page 131 131
  • Page 132 132
  • Page 133 133
  • Page 134 134
  • Page 135 135
  • Page 136 136
  • Page 137 137
  • Page 138 138
  • Page 139 139
  • Page 140 140

Woods AC CAPRI Silent 9K Operating Instructions Manual

Tüüp
Operating Instructions Manual
See käsiraamat sobib ka