Tronic WMS dongle
With the “Tronic WMS Configurator” you can:
Read and change parameters
Set maximum temperature (hot water limitation)
Initiate hot water flushing
Take notes
View and save signal strengths
System Requirements
Recommended Windows 10 (PC)
Requires Windows 10 (tablet)
Installation
1. Download and install “Tronic WMS Configurator” software from
www.fmmattsson.com/download or www.moraarmatur.com/download
2. Connect the dongle via the USB port to your PC or tablet
3. Start the “Tronic WMS Configurator” application
Connection
1. Put nearby mixer in service position using the service magnet. Hold it against the sensor for
at least 10 seconds (see picture)
2. When the mixer is in service mode, it will be displayed within 1 minute (see pictures)
3. Click on the mixer image.
4. Enter a unique name for the mixer and press "Change"
5. You can also save a note attached to the mixer and press "Add"
6. You can now repeat paragraphs 1-5 for other mixers within the range of the dongle.
Mixers default ID
Mixer type
Radiocommunication
Battery/Main status
Service mode
Battery level
Updated
Number of activations
Signal strength
Set parameter
1. Click "Set parameter"
2. The image below is shown, here you can choose which mixer to program by clicking on it
once, marked with a black line on the left side.
Presets
1. Click on the desired value, the default value is shown above each group.
2. Changed values are transmitted to the mixer, when the mixer is updated, the green symbol is
then displayed. Transmission takes place faster if the mixer is in service mode.
Settings
1. "Load values from mixer" - Uploads the actual values from the mixer. Transmission takes
place faster if the mixer is in service mode
2. "Load defaults" - Resets the mixer to factory settings. Transmission takes place faster if the
mixer is in service mode
3. "New value" - Enter the desired value within the specified interval, for info click on the
respective heading. Send the value by pressing "Send". Transmission takes place faster if the
mixer is in service mode
4. Set values can be saved by pressing “Save Program”, enter a name and press OK.
5. To select a saved program, select "Load program", programs will be deleted with "Delete
program"
6. When the mixer is updated, the green symbol appears
Service
Not used
Hot water flush
1. Click on "Hot Water Flush"
2. Select mixer to be flushed, marked with a black line on the left side. Press "Next"
3. Adjust the mixer valve/thermostat for hot water flushing according to the mixer instruction,
if the instruction is missing, it is available at www.fmmattsson.se or www.moraarmatur.se
4. Then follow the on-screen instructions.
5. IMPORTANT, remember to recover the valve/thermostat after hot water flushing.
Notes
Here you have the possibility to save notes, the notes are stored locally on a computer /
tablet.
Save signal strengths
1. Click on "Save Signal Strengths"
2. Here you can save an image that shows current signal strengths
3. Name the image and press "Save"
4. The image is saved as a local file on a computer / tablet.