6
6 | M16MI364 - A04 - 04/18
INSTALLATION AND MAINTENANCE OF YOUR RADIATOR
EN
STANDARDS Double Insulation Category II - IK09 - - IP44*
These radiators comply with standards EN 60.335-1, 60.335-2-30. These
appliances benefit from a double insulation on the electrical parts -
category II are protected against water ejections (IP44*) and benefit from
mechanical shock resistance (IK09). They also comply with the European
directive 2004/108/EC (EC marking on all appliances).
These appliances are not made to be used by people (including children)
with limited physical, sensorial or mental capabilities or people devoid
of experience or knowledge unless they have been able to benefit from a
person responsible for their safety or from prior supervision or
instructions concerning the use of the appliance. It is advisable to super-
vise children to ensure they do not play with the appliance.
LOCATION
To fully enjoy your appliance and for your greatest convenience, please
consider the following recommendations:
• The lower part of the thermostat must be at least 150 mm from the
floor.
• The appliance must not be installed less than 40 mm from a wall nor
below a socket.
• Any shelf put above the radiator must be at least 150 mm from it.
• It is recommended to install the radiator near locations with strong
heat loss (windows…), and to use fixing screws adapted to the nature
of your wall and to the weight of the appliance.
This appliance must never be installed with its thermostat in a high
position. The thermostat must not rest on the floor. Simply use wedges
when installing to protect it.
CONNECTION
The technical features of your appliance are indicated on its nameplate
situated on the radiator, close to the thermostat. Please take note of this
before any after-sales intervention.
Power is supplied by 230-240 V~/50Hz or by 400 V~/50Hz. An all-pole
switch is compulsory. The separation distance between contacts must be
at least 3 mm. Connect the cable of the terminal board of the cable
adaptor by following the following instructions:
230-240V
• Brown wire = Phase (Pin 1),
• Grey or Blue wire = Neutral (Pin 2),
• Black wire = Night reduction signal or external clock (Pin 3, not to
earth). The black cable provides drop in temperature if it is connected
to Neutral. It must never be connected to the earth and must be insu
lated from any contact if not used.
400V
• Brown wire = Phase 1 (Pin 1),
• Grey or Blue wire = Phase 2 (Pin 2),
• Black wire = Night reduction signal or external clock (Pin 3, not to
earth). The black cable provides drop in temperature if it is connected
to Neutral. It must never be connected to the earth and must be insu
lated from any contact if not used.
The power cable originally provided must be connected to the network
by a connection box that should be placed behind the appliance, free
from a wall socket and situated at least 250 mm from the floor (kitchen
& bathroom).
For Yali GV, Sanbe, Langila: The grey connector may, if so desired, be
covered by the supplied protection box, see pictures.
If the power cable is damaged, it must be replaced by a specific cable.
This cable must be replaced by the manufacturer, its after-sales service or
people with similar qualifications to avoid any hazard.
SPECIAL INSTALLATION RULES CONCERNING BATHROOMS
In addition to the rules stipulated
in these instructions, the
appliances must be installed
in accordance with applicable
standards and good engineering
practice.
This appliance is IP44*. It is there-
fore protected against water
ejections and can be installed in
volumes 2 and 3, provided that
the thermostat cannot be reached
by a person using the bath or
shower (i.e. the thermostat must
be installed in volume 3). It must
not be connected to a ground
terminal.
• A ground fault circuit interrupter of 30mA maximum is compulsory
for bath rooms or shower rooms.
• Switches and controlling devices can be placed by ensuring they can
not be reached by anybody using the bath or shower.
USE
WARNING - In order to avoid overheating, do not cover the
heater.“Do not cover” means that the radiator must not be
used for drying clothes, for example, by placing them directly
on the radiator.
For the working of the electronic control refer to the instructions pro-
vided with the RF transmitter.
MAINTENANCE ADVICE
Maintenance must be carried out on a turned off radiator. Therefore
ensure the appliance is disconnected from the electric network before
doing any manintenance. To ensure the longevity of your radiator, we
recommend applying the following advice:
• Use a dry cloth (without solvent) for the control unit,
• Use warm soapy water to look after the radiator's external walls (no
abrasive or corrosive product).
This heating appliance is filled with a precise quantity of coolant, special
oil or glycol water depending on the appliance. Repairs requiring the
tank to be opened must only be carried out by the manufacturer or its
after-sales service that must be contacted in the event of an oil or glycol
water leak. This fluid, specially developed for this use requires no special
maintenance.
When scrapping the heater, follow the regulations concerning the
disposal of oil.
ENVIRONMENTAL REGULATIONS
ROHS: Complies with directive 2002/95/EC
DEEE: Complies with directive 2002/96/EC
Handling electrical and electronic appliances at the end of their shelf life
This symbol indicates that this product must not be processed
with household waste. It must be taken to a suitable collection
point that will look after recycling it. By discarding this product
appropriately, you will help prevent any possible negative
consequences for the environment and human health. When the
heating appliance is discarded, respect the regulations concerning the
disposal of the oil.
*) IP44 when the water protection cover (that is supplied) is mounted.
If the product is installed only with the connection box the product is IP21
WARRANTY
The warranty is valid for 10 years except for electrical compo-
nents which is valid for 2 years. In the event of any problems or