4
WETTED COMPONENTS
Aluminium, Steel, Cast Iron, Nylon, NBR, Zinc, Polypropylene, PVC
RECOMMENDED USE
Oils up to a viscosity of SAE 90, Synthetic Oils, Antifreeze*,
Used Oil, Hydraulic Fluids, Cutting Oils, Oil based herbicides, Non
Flammable Oil Based Solvents, Liquid Soap* etc.
* for use with water based fluids, the additive to water must
contain corrosion inhibitors
PUMP SPECIFICATIONS
• This is not a fuel pump
• Max. 20 Starts / Hour: Time gap between Motor
Stop & Restart must be min. 3 minutes.
8. Motor is Air Cooled & Thermally Protected which means that
the pump can be run for a very long time. If due to any reason,
the motor gets heated, it will stop automatically
9. The pump however must never be run dry (no media in the
drum) as that can possibly cause irreparable damage to the
motor
10. In case ball valve is used to control flow & is closed with the
motor on, there will be no media flowing out of the discharge
spout; instead media will go back into the pump. Pump has
a built-in Bypass valve that will get activated & bypass the
media. The ball valve however must never be kept close
for more than 5 minutes with the motor switched on
11. Once Dispensing is completed, switch off the toggle switch &
disconnect the power cord from the AC outlet
12. Store the Discharge Spout into the ¾” hole on the drum
DO NOT USE WITH
Fuels, Corrosive Media, Acids, Chemicals, Lacquers, Paint
Thinners etc.
PUMP OPERATION
1. Switch On Power from the AC Outlet
2. Make sure that the Ball Valve is in open position (valve
parallel to the hose)
3. Dispensing Spout should be facing the container into which
media is to be dispensed
4. Now Switch On the Motor by Pressing the Toggle Switch Down
5. In less than a minute, the pump will be primed & media will
start dispensing from the Steel Outlet Spout
6. Dispensing Action can be stopped by Switching off the Toggle
Switch on the Motor. It is suggested not to close Ball Valve to
Stop flow.
7. Max. 20 Starts / Hour: Time gap between Motor Stop &
Restart must be min. 3 minutes.
Ball Valve is not designed to be used to control flow, but
used primarily as a non drip which is closed after motor is
shut down
115V AC Pump 220V AC Pump
Flow Upto 4.4 GPM (16.6 LPM) 3.7 to 4.4 GPM ( 14 to 16.6 LPM)
Motor ½ HP 115V AC , 60 Hz. ½ HP 220V AC , 50/60 Hz.
Amp 9 Amp 6 Amp
RPM 1720 1400 / 1720
Construction – Pump Housing Aluminium Die Cast Aluminium Die Cast
Mechanism Gear Pump Gear Pump
Gear Material Sintered Powder Metal Sintered Powder Metal
Internal By-Pass Valve Yes Yes
Suction Pipe 34” Long 34” Long
Hose 8’ long x ¾” ID 8’ Long x ¾” ID
Bung Adapter 2” Threaded 2” Threaded
Inlet 1” NPT (F) 1” NPT (F)
Outlet ¾” NPT (F) ¾” NPT (F)
Dispensing Nozzle Ball Valve Ball Valve
Power Cable Included Included
Air Cooled Yes Yes
Max. Viscosity of Oil SAE 90 SAE 90
Max. Working Pressure 65 PSI (4.5 BAR) 65 PSI (4.5 BAR)
Thermal Protection Yes Yes