SkyLink SW-101U Kasutusjuhend

Tüüp
Kasutusjuhend

See käsiraamat sobib ka

ZONE LED DESCRIPTION
Off Zone is not occupied by any control module
Flashes once This zone is occupied by another control module.
Programming another remote to this zone will overwrite
the previous control module.
Flashes twice This zone is occupied by a remote. You can still
program a control module to this zone, and it will not
overwrite the remote you have in this zone.
1. INTRODUCTION
Skylink
®
Control Module
Model SW-101F/
SW-101G/SW-101U
Both control panel and control module are transceivers, meaning they can transmit
and receive signals from each other. For home automation, the user will initiate an
action from the control panel, such as sending a signal to turn on the light, then the
control module will receive such signal and respond. The control module will then
send back a confirmation to the control panel to indicate the light has been turned on.
Therefore, during programming, it is required to program 2 things:
1. Signal from control module to control panel (confirmation signal)
2. Signal from control panel to control module (command signal)
Turn on
(command
signal)
Confirm on
(confirmation
signal)
Control
Panel
Control
Module
2
3
4
Step Keys Function Description Note
1
[PROG]
[MPIN]
Enter
Programming
mode
Enter master
password to
programming
mode
3 beeps for valid
password. 1 long beep for
invalid password.
Select learn
control module
programming
After [4] is entered, some
zone LEDs will flash or stay
off. The zone LEDs
represent whether that zone
is already occupied by
another control module.
**See Table A.
[4]
[1] to [5] After you have selected the
control module location, that
zone LED will be on.
Select control
module location
(Max. 5 control
modules)
Select the location
[1], [2], [3], [4], or
[5].
Activate the
control
module by
pressing its
learn button
once quickly.
Send signal
from control
module to
control panel.
Once the signal
is transmitted to
the Control Panel,
that signal will be
stored.
You will hear
[Device X Accepted],
where “X” is the control
module location.
2. PROGRAM THE CONTROL MODULE TO THE
AAA+
TM
CONTROL PANEL (CONT)
** Table A: Zone LED status for learning control module.
Flashes once,
then twice
This zone is occupied by a remote AND a control
module. If you program another control module to this
zone, it will overwrite the previous control module, but
not the remote.
Control Module [1] is represented by zone LED 1
®
This row :
Buttons for
Learning Control Module
Part 2 Learn signal from Control Panel to Control Module
1
2
Step Keys Function Description Note
Enter
Programming
mode
LED on the Control
Module will flash
indicating it is in
learn mode.
Press and
hold the learn
button on the
Control
Module until
its LED starts
to flash.
[6] to [0] Transmit an ON
signal for the
selected device
from the Control
Panel to the
Control Module.
Refer to the chart
below to determine
which button [6] to
[0] to press.
You should transmit
the “ON” command
for the selected
device.
After [X] is entered, you will
hear [Device X On]
indicating you have trans-
mitted an ON signal for
device X, where X is the
Control Module Location.
The LED on the Control
Module should be off,
indicating it has learned the
signal, you may now release
the learn button and the LED
will stay on again.
Part 1 Learn signal from Control Module to Control Panel
CONTROL MODULE
LOCATION
1 6
2 7
3 8
4 9
5 0
TRANSMIT
BUTTON [X]
The Skylink control module Model SW-101 is designed to operate plug in lighting
or appliance. It is a wireless transceiver. It can receive signal from AAA+
TM
control panel or other sensors (transmitters) to turn on / off the plugged in
lighting / appliance.
There are 3 different versions of the Skylink Control Module SW-101. Each
version is designed with specific plug:
In this is manual, all these models will be referred as model SW-101.
For operation with AAA+
TM
control
panel, follow instructions from
section 2 to section 3.
For operation with AAA+
TM
sensors
directly, follow instructions from
section 4 to section 6. (Only
applies if you do not have the
AAA+
TM
control panel.)
2. PROGRAM THE CONTROL MODULE TO THE AAA+
TM
CONTROL PANEL
To turn off a light with the control panel:
1. Press the device number button on the control panel, i.e. pressing 1 will turn
off device 1, pressing 2 will turn off device 2.
2. You will hear [Device X Off], where X is the device number.
3. You will also see the PROG LED flashing, indicating the control panel is
sending out the wireless signal to control the specific device.
4. If the receiver receives the signal, the control panel will announce [Device
Off Accepted].
3. OPERATION
Control
Module
SW-101U
UK Plug
Control
Module
SW-101F
French Plug
Control
Module
SW-101G
German Plug
To turn on a light with the control panel:
1. Press the number below the device number that you would like to turn on, i.e.
pressing 6 will turn on device 1, pressing 7 will turn on device 2.
2. You will hear [Device X On], where X is the device number.
3. You will also see the PROG LED flashing, indicating the control panel is
sending out the wireless signal to control the specific device.
4. If the receiver receives the signal, the control panel will announce [Device
On Accepted].
10. WARRANTY
If, within one year from date of purchase, this product should become
defective (except battery), due to faulty workmanship or materials, it will
be repaired or replaced, without charge. Proof of purchase and a Return
Authorization are required.
If you would like to order Skylink’s products or have difficulty getting them to
work, please :
1. visit our FAQ section at www.skylinkhome.com , or
2. email us at [email protected], or
3. call our toll free at 1-800-304-1187 from Monday to Friday, 9 am to 5 pm EST.
Fax (800) 286-1320
11. CUSTOMER SERVICE
There are different operating modes with the control module. If you are controlling
the control module with AAA+
TM
, it is recommended setting the control module in On
/ Off mode (factory default setting), so the plugged in lighting / appliance can be
controlled by the AAA+
TM
numeric keys. However, if you would like the plugged in
device to stay on for 3 minutes or flashes for 3 minutes when turn on the device
from the numeric keys, please follow Section 5 – OPERATION MODES to change
the setting.
When a sensor is trigger, the control module will be turned on. To program a sensor
to the control module, follow the instructions below.
1. Press and hold the learn button on the control module until its LED starts to flash.
2. Activate the sensor you would like to program to the control module.
Note: If you would like to turn on the plugged in light when the door is open, you
should activate the sensor by opening the door. If you activate the sensor by
closing the door, the light will be turned on when the door is closed.
3. Once the sensor is programmed to the control panel, the LED will be off. You
may now release the learn button and the LED will stay on.
Note: One control module can learn up to 16 different sensors. When multiple
sensors are programmed to one control module, one sensor may turn on the control
module and another sensor may turn off the control module. So please ensure
there is no conflict for your application.
4. PROGRAM THE CONTROL MODULE TO THE AAA+
TM
SENSOR
There are 3 different operating modes on the control module:
1. On / Off mode
Turn on the plugged in device when the control module receives a on / open
signal from the sensor. Turn off the plugged in device when the control module
receives a off / close signal from the sensor.
Example:
Door / Window sensor: Turn lights on when the door is open, turn lights off when
the door is closed. Water sensor: Turn lights on when water is detected, turn
lights off when water is not detected.
Note: Motion Sensor cannot operate properly with a control module in on / off
mode, because there is no off signal from a motion sensor.
2. Timer mode
Turn on the plugged in device for 3 minutes when the sensor is triggered. It will
automatically be turned off after 3 minutes.
Example:
Motion Sensor: Turn lights on when movement is detected for 3 minutes, then
turn lights off.
Door Sensor: Turn lights on when the door is open for 3 minutes, even the door
is only opened for 5 seconds, the lights will remain on for 3 minutes.
3. Flashing mode
Flashes the plugged in lighting for 3 minutes when a sensor is triggered. After 3
minutes, the light will be off automatically.
Example:
Motion Sensor: Flashes light when movement is detected for 3 minutes, then the
lights off.
Tips: You can program the control module into this operating mode with the panic
signal from the AAA+
TM
. When the alarm is triggered, the plugged in light will
flash to draw the attention of your neighbor or police.
To set different operating mode, follow the instructions below:
1. Remove the screw with a Philips screw-
driver and open the cover.
2. Place the connector so it refers to the
operating mode you prefer.
3. Close the cover and secure the screw.
5. OPERATING MODES
7. ERASE CONTROL MODULES
To erase a control module from the control panel, please refer to the AAA+
TM
User’s Instructions.
To erase a sensor or AAA+
TM
control panel from the control module, you must
first erase all the programmed sensor(s) / AAA+
TM
control panel from the control
module, then learn the ones you would like to Follow the instructions below to
erase all the programmed devices in the control module:
1. Unplug the control module from the wall AC socket.
2. Unplug the lighting / appliance from the control module, if any.
3. Press and hold the learn button.
4. Plug in the control module to the wall AC socket while holding on to
the learn button. The LED will flash quickly indicating the programmed
device(s) are all erased.
5. You may now release the learn button, and the LED will stay on.
You can now program the sensor(s) / AAA+
TM
control panel you wish to work with
the control module based on programming instructions in the user’s instructions.
3. OPERATION (CONT)
8. CAUTION
9. OTHER AAA+
TM
ACCESSORIES
The AAA+
TM
control panel can work with different accessories include: Garage door
monitor
TM
sensor, Indoor/outdoor motion sensor, Audio sensor, Remote control,
Audio Alarm, etc. Please visit www.skylinkhome.com or contact us at
[email protected] for more information of how to fully utilize your AAA+
TM
control panel.
6. OPERATION
Trigger the programmed sensor / AAA+
TM
control panel, the control module should
react to the signal and activate the plugged in lighting / appliances.
On / Off mode
Flashing mode
Timer mode
CAPITAL PROSPECT LTD.
Rm.1303, 13/F, Block B, Veristrong Ind. Centre,
36 AuPuiWan Street, Fo Tan, Hong Kong
Tel: +852 2602-1318 Fax: +852 2602-4684
http://www.skylinkhome.com
P/N. 101A429
©2006 SKYLINK GROUP
RISK OF ELECTRICAL SHOCK. FOR INDOOR USE ONLY.
CAUTION : NOT FOR USE WITH DIMMER.
DISCONNECT POWER BEFORE CODE SETTING.
REPLACE COVER AFTER CODE CHANGING.
Maximum Rating :
Input : 230VAC 50Hz Incandescent : 500 watts
Resistive load : 6A (1500W) Motor Load : 1/3 HP
  • Page 1 1
  • Page 2 2

SkyLink SW-101U Kasutusjuhend

Tüüp
Kasutusjuhend
See käsiraamat sobib ka

teistes keeltes