Dante DLC1981 Kasutusjuhend

Kategooria
Turvakaamerad
Tüüp
Kasutusjuhend

See käsiraamat sobib ka

DLC1981-DLC1982-DLC1985
Color & D/N PTZ Domes
Installation and Operations Manual
Model Number: DLC1981-DLC1982-DLC1985
Description: PTZ Domes Indoor/Outdoor
18x (1/3”), 22x 26x, 30x, 35x, 36x Zoom
CONTENTS
FEATURES ................................................... 4
DECLARATION ........................................... 6
PRECAUTION .................................. 6
WARNINGS ...................................... 6
INSTALLATION PREPARATION ............... 7
TOOL LIST ....................................... 7
CABLES ............................................ 7
DIP SWITCH SETTING ................... 7
CONNECTION DIAGRAM .............. 7
MOUNT TYPE .............................................. 8
IN-CEILING MOUNT ....................... 8
SURFACE MOUNT .......................... 8
WALL MOUNT ................................. 8
CORNER MOUNT ............................ 9
POLE MOUNT .................................. 9
PENDANT MOUNT .......................... 9
INSTALLATION GUIDE ........................... 10
IN-CEILING MOUNT ..................... 10
SURFACE MOUNT Error! Bookmark
not defined.
WALLMOUNT ................................ 12
CORNER MOUNT .......................... 14
POLE MOUNT ................................ 16
PENDANT MOUNT ........................ 18
S Y S T E M C O N N E C T I O N ................... 21
O P E R A T I O N I N S T R U C T I O N ......... 22
PREHEATING SCREEN ................. 22
BOOT-UP SCREEN ........................ 22
ACCESS MAIN MENU ................... 23
M E N U O P E R A T I O N ........................... 24
SELECTING ITEM.......................... 24
CHANGING VALUE ...................... 24
EDITING TITLE .............................. 24
S Y S T E M I N F O ...................................... 25
SITE INFO ....................................... 25
DISPLAY SETUP ........................... 26
BOOT-UP SCREEN ......................... 26
PASSWORD .................................... 26
SET DEFAUT .................................. 27
SYSTEM REBOOT ......................... 27
L E N S P A R A M E T E R S ......................... 28
ZOOM SPEED ................................ 28
DIGITAL ZOOM ............................ 28
JOYSTICK AF/AI ........................... 28
AF RESUME TIME ......................... 28
AI RESUME TIME .......................... 29
IRIS ALC ......................................... 29
IRIS PLC .......................................... 29
DAY/NIGHT .................................... 29
C A M E R A P A R A M E T E R S ................. 30
FRAME LIMIT ................................ 30
SHUTTER ........................................ 30
EXPOSURE ..................................... 30
PRESET FREEZE ............................ 30
WHITE BALANCE .......................... 31
BLC MODE ..................................... 31
P A N / T I L T P A R A M E T E R S ............... 32
AUTO STOP TIME ......................... 32
SPEED AMPLIFY ........................... 32
PROPORTIONAL P/T .................... 32
SET NORTH .................................... 32
A U T O R U N N I N G ................................. 33
PRESET ........................................... 33
TOUR ............................................... 34
PATTERN ....................................... 35
INSTRUCTION
MANUAL
CRUISE .......................................... 36
ZONE ............................................... 37
PARK TIME .................................... 38
PRIVACY MASK ............................ 39
ALARM .......................................... 40
APPENDIX I : Special Function Operation .. 41
APPENDIX II : DIP SWITCH SETTINGS .. 42
APPENDIX IIIWIRE DIAMETER &
TRANSMISSION CHART ..... 47
APPENDIX IVRS-485 BUS BASIC
KNOWLEDGE ....................... 48
APPENDIX V TROUBLE SHOOTING .. 50
APPENDIX VILIGHTNING PROOF &
SURGE SIGNAL PROOF ...... 51
APPENDIX VIIWARRANTY .................. 52
4
FEATURES
Product Features
Multiple Zoom camera blocks optional
Graceful outlook, Vandal proof available
System preheat in low temperature environment
Programmable Multi-protocol
Multi-language menu (China, Britain, France, Germany, Russia,
Italy, Portugal, Spain), friendly interface, easy to operate
360° continuous pan, 180° Tilt “Auto Flip”
8 tours(32presets/tour), 8patterns, 8 cruise
8 Privacy Mask, 8 titled zones
Port for Software up-grade
Built-in Alarm, 8 Inputs/4 Outputs
Built-in Surge and Lightning Protection
Speed Amplify to fit different control keyboard
Auto Running Memory Against Power Outage
Auto Running Resume after Manual Operation
On-Screen display for compass and tilt angle,
System and environment temperature, fan status
Dome Drive Unit
360° continuous pan, 180°Tilt “Auto Flip”
Discreet Liner with Sealed Fixed Bubble
256 presets, ±0.1° preset accuracy
320°/s Pan/Tilt 400°/s Preset Speed
8 tours max. 27 presets/tour
8 patterns, 4 cruises, 8 titled zones
8-24 privacy masks
OSD Menu password protection
Built-in alarm, 7 input/2 output
Multiple RS-485 protocol/Coaxial
Locations of Labels and On-Screen Displays
Software Up-gradable via RJ-45
FIFO alarm priority levels
Alarm driven Pattern, preset etc.
Position Resume After Alarm
Variable Cruise Speed 0.1-150°/sec
OSD Menu for Programmable Functions
Proportional Pan/Tilt Speed
Vertical Tilt Unobstructed 0° to -95°
Auto Running Memory Against Power Outage
Auto Running Resume after Manual Operation
System preheat before camera power on
On-Screen display for compass and tilt angle,
System and environment temperature, fan status
Environment
Operating Temperature
Model
Absolute Max
Sustained Max
Absolute Min
Sustained Min
In
-
Ceiling Indoor
Standard Pendant
113°F (45°C)
95°F (35°C)
-
F (
-
20°C)
14°F (
-
10°C)
Env
ironmental Mount
1
58
°F (
7
C)
1
40
°F (
6
C)
-
60°F (
-
51°C)
-
50°F (
-
45°C)
Note:
1. Assume no wind chill factor
2. Prevents icing at sustained minimum of -50°F (-45°C)
3. De-ices 0.1 inch (2.5 mm) within 3 hours after power-up
TECHNICAL SPECIFICATIONS
Electrical
Input Voltage 16-30 VAC; 24 VAC nominal
Input Power 10 VA nominal (w/o heater)
45 VA nominal (with heater)
Fuse 1.25A
Auxiliary Outputs 2 Alarm Inputs 7
Built-in Surge Protection
Limited Lightning Protection
General
Construction
Back Box & Housing Die-cast Aluminum
Dome Drive Aluminum, thermo
plastic
Bubble Acrylic/Poly Carbon
5
Camera/Options
Accessories
Mounting
Wall mount bracket
Pendant mount accessory
Corner mount accessory
Pole mount accessory
Heating
Outside temperature sensor
Transmitting & Controlling
Up-the-Coax/RS-485 converter
Manchester Code or Biphase Code/RS-485 converter
Cam. Parameters DLC1982-26X D/N w/ICR DLC1985–30X D/N w/ICR DLC1985–35X D/N w/ICR DLC1985–36X D/N w/ICR
Image Sensor ¼”
Sony CCD
¼ Hitachi CCD ¼” Hitachi CCD ¼” SONY EXview HAD
Resolution 480/570BW TVL 540/650BW TVL 540/650BW TVL 550/680BW TVL
Effective Pixels NTSC 380k / PAL 440k NTSC 410k / PAL 470k NTSC 380k / PAL 410k NTSC 380k / PAL 440k
Signal Format NTSC/PAL NTSC/PAL NTSC/PAL NTSC/PAL
Video Output 1V p-p (sync negative) 1V p-p (sync negative) 1V p-p (sync negative) 1V p-p (sync negative)
Lens 26X SONY
30X Hitachi WDR / Image
Stabilizer
35X Hitachi WDR / Image
Stabilizer
36X Sony WDR / Image
Stabilizer
Focal Length f=3.5mm(W)~91mm(T) f=3.4mm(W)~102mm(T)
f=3.4mm(W)~119mm(T) f=3.4mm(W)~122.4mm(T)
Aperture
F1.6~F3.8
F1.4~F3.6 F1.4~F4.2 F1.4~F4.5
Digital Zoom 12X 12X 12X 12X
Min. Working Dist. 320mm(W)~1500mm(T) 55.8° (Wide) to 2° (Tele) 55.8° (Wide) to 1.7° (Tele) 320mm(W)~1500mm(T)
Sync System internal/external (V-lock) internal/Line-lock internal/external (V-lock) internal/external (V-lock)
S/N Ratio >50dB >50dB >50dB >50dB
Min. Illumination @ 35
IRE 1.0/0.15Lux/BW 0.1/0.01BW/LUX
0.018LUX @ 1/2sec Color /
0.0001LUX @ 1/15sec BW
0.018LUX @ 1/2sec Color /
0.0001LUX @ 1/15sec BW
IRIS Auto/Manual Auto/(offset software) Auto/(offset software) Auto/Manual
Focus Auto/Manual Auto/Manual Auto/Manual Auto/Manual
White Balance Auto/Manual Auto/Manual Auto/Manual Auto/Manual
Gain Auto/Manual 0-30dB via software 0-30dB via software Auto/Manual
BLC / WDR Auto/Manual ON/OFF
ON/OFF
ON/OFF
6
DECLARATION
This equipment generates, uses, and can radiate
radio frequency energy and, if not installed and used
in accordance with the instruction manual, may
cause harmful interference to radio communications.
Operation of this equipment in a residential area is
likely to cause harmful interference in which case the
user will be required to correct the interference at
the user’s own expense.
PRECAUTION
Only qualified and experienced person can
carry out the installation. In many
countries and areas licensed personnel is
required
Always take safety codes into
consideration during installation.
Use reliable tools only, poor quality tools
may cause damage to both human and
property
Check the strength of all item onsite that
are related to installation in advance. It is
recommended that the stand of dome be 8
times stronger than the weight of the dome
and its accessories.
Keep all the original dome package
materials in case of future repacking and
transportation.
Choose and install speed dome according
to environment requirement (Refer to the
Product Features). This product conforms
to IP66 standard as specified in “Housing
Protection Classification (IP code)”.
WARNINGS
Avoid installing this speed dome in
hazardous places where inflammable or
explosive materials are stored or used.
Indoor dome is not designed for outdoor
environment.
This speed dome runs on 24VAC.
Connect to power only after completing
installation.
Disassemble can only be carried out by
qualified personnel.
Use soft towel to clean the lower cover
when necessary. Avoid using caustic
detergent.
Avoid aiming camera to strong light.
7
INSTALLATION
PREPATATION
TOOL LIST
Following tools may be needed for the installation:
Screws and nuts
Philips screw driver
Standard screw driver
Wire scissors
Ladder
Drill
Saw.
CABLES
Video Coaxial Cable
75
impedance,
Solid copper wire,
95% braided copper shield.
Check the max transmission distance referring to the
chart below.
Model
Distance
RG 59/U
750ft(229m)
RG 6/U
1,000ft(305m)
RG 16/U 1,5000ft(457m)
RS-485 Cable
0.56mm (24AWG) twisted pair wire
DIP SWITCH SETTING
Refer to appendix I:
Protocol and Baud rate
Dome address
Video cable type
Resistor jumper
Alarm output method
CONNECTION DIAGRAM
POWER RS-485 Sensor
AC
24VAC
GROUND
AC
24VAC
NO
NONE
RX-
RS-485 B
RX+
RS-485 A
S-
Temperature Sensor -
S+
Temperature Sensor +
Alarm Socket
Alarm In (1-7): Alarm Input (1-7), NC
Alarm In Com: Common port of alarm in
Relay Out (1-2): Alarm relay (1-2), NC or NO
selectable
- 8-
MOUNT TYPE
IN-CEILING MOUNT
SURFACE MOUNT
WALL MOUNT
225
247
16
5
100
225
- 9-
CORNER MOUNT
POLE MOUNT
PENDANT MOUNT
- 10-
INSTALLATION GUIDE
IN-CEILING MOUNT
Maximum thickness of the ceiling is 42mm and the
ceiling should be able to hold 8 times of the weight of
the speed dome. More than 20cm of clear space is
needed above the ceiling.
1. Mark the hole on ceiling.
Mark a φ
φφ
φ225 mm circle on the proper position of
the ceiling using the accessory paper sheet
2. Make the hole.
Cut the hole with proper tool. Make sure the
tolerance is less than +2mm.
225
3. Unfasten the circuit board.
Unscrew the screw to open the circuit board on
connection board.
4. Connect cables.
Prepare wiring and then put Power/RS-485/ Video
cables through waterproof connector on the top of
housing. Turn the connector into the top hole of the
housing
5. Connect cables.
Plug cables into corresponding sockets on circuit
board. When finished, fix the circuit board back
and turn on the power. The red LED will light.
Turn off the power after checking.
NOTE: There are signs for each port. Fix cables as
picture shows. Make sure power is off before
connecting.
- 11-
6. Adjust clips.
Adjust the height of the three mounting clips.
Swing the three mounting clips to adhere to
housing.
7. Install housing.
Push housing into ceiling and let the clips stretch
out. Finally, screw the three clips to tighten the
housing
8. Set dome ID, baud rate and protocol.
Set dome ID, bard rate and protocol by configuring
DIP switches (Refer to APPENDIX I).
NOTE: Remove the packing sponges.
9. Install Pan/Tilt Module.
Push the black liner into the two tabs. Install the
pan/tilt module with two clips, match color of AMP
sockets. Gently push the module upward until
hearing two clicks.
NOTE: Remove the lens cover
10. Install lower cover.
Fasten the safety chain on housing. Align clasps
and mounting holes then turn clock-wise.
NOTE: Let the safety chain inside the arc groove of
the lower cover, otherwise it may scratch the lens.
-12-
WALLMOUNT
Check carefully to make sure the wall is firm and does
not peel off. It is required that the wall can withstand 8
times weight of the dome set.
1. Mark mounting position
Use bracket to mark the mounting position on wall.
2. Install bracket.
Connect all cables through the hole of bracket, and fix
bracket on the wall.
NOTE: Put cables through the wall or aside the
bracket.
3. Release the connection board.
Unscrew to release the circuit board on connection
board.
4. Install housing
Connect cables through the hole on top of the housing.
Align the fast connector to bracket and fix with 2 M5
screws.
NOTE: Apply water-proof tape to the thread in the case
of outdoor dome
5. Connect cables.
Plug cables into corresponding sockets on circuit board.
Reinstall the circuit board and turn on the power. The
red LED is on if connections are correct. Turn off the
power after checking.
NOTE: Names of the interfaces are marked on terminal
block or PCB. Connect cables as picture shows. Make
sure power is off before connecting.
ALARM
VI DEO
RS485, AC24V
-13-
6. Set dome ID, baud rate and protocol.
Set dome ID, bard rate and protocol by configuring
DIP switches (Refer to APPENDIX I).
7. Lower cover preliminary installation.
Attach the safety chain with a M3 nut as picture shows.
8. Install black liner and Pan/Tilt Module.
Push the black liner into the two tabs. Install the pan/tilt
module with two clips, match color of AMP sockets.
Gently push the module upward until hearing the click.
NOTE: Remove the lens cover
Tab
Bl ack Li ner
9. Install lower cover.
Unscrew the two M4 screw on lower cover ring. Push
up the lower cover into the housing and then fasten
lower cover with two M4 screws.
NOTE: Apply lube to the O-ring in the case of outdoor
dome
lube
M4 slot
-14-
CORNER MOUNT
Check carefully to make sure the wall is firm and does
not peel off. It is required that the wall can withstand 8
times weight of the dome set.
1. Mark the fastener positions.
Use the corner mount base as the template to mark
the mounting positions on wall.
2. Install base.
Put Power/RS-485/ Video cables through the hole
of corner mount base and use M8 nuts to fasten
corner base on the mounting surface.
NOTE: Put cables through the wall of aside the
corner base
3. Install bracket.
Put cables through the cavity of bracket and fasten
bracket on base
4. Release the connection circuit board.
Unscrew to release the circuit board on
connection board.
5. Install housing.
Connect cables through the hole on top of the
housing. Align the fast connector to bracket and fix
with 2 M5 screws
NOTE: Apply water-proof tape to the thread in the
case of outdoor dome
-15-
6. Connect cables.
Plug cables into corresponding sockets on circuit
board. Reinstall the circuit board and turn on the
power. The red LED is on if connections are
correct. Turn off the power after checking.
NOTE: Names of the interfaces are marked on
terminal block or PCB. Connect cables as picture
shows. Make sure power is off before connecting
ALARM
VI DEO
RS485, AC24V
7. Set dome ID, baud rate and protocol.
Set dome ID, bard rate and protocol by configuring
DIP switches (Refer to APPENDIX I).
8. Lower cover preliminary installation.
Attach the safety chain with a M3 screw as picture
shows.
9. Install black liner and Pan/Tilt Module.
Push the black liner into the two tabs. Install the
pan/tilt module with two clips, match color of AMP
sockets. Gently push the module upward until
hearing two clicks.
NOTE: Remove the lens cover.
Tab
Bl ack Li ner
10. Install lower cover.
Unscrew the two M4 screws on lower cover ring.
Push up the lower cover into the housing, and then
fasten lower cover with two M4 screws.
NOTE: Apply the lube to the O-ring in the case of
outdoor dome
lube
M4 slot
-16-
POLE MOUNT
Pole mount is applicable to installation on pole with
diameter of 130-150mm (5.12~6)
1. Install base.
Put Power/RS-485/ Video cables through the
central hole of the bracket base, and then fix it to
the pole
2. Install bracket.
Put cables through the cavity of bracket and fasten
it on base.
3. Release the circuit board.
Unscrew to release the circuit board on connection
board.
4. Install housing.
Connect cables through the hole on top of the
housing. Align the fast connector to bracket and fix
with 2 M5 screw
NOTE: Apply water-proof tape to the thread in the
case of outdoor dome
5. Connect cables.
Plug cables into corresponding sockets on circuit
board. Reinstall the circuit board and turn on the
power. The red LED is on if connections are
correct. Turn off the power after checking.
NOTE: Names of the interfaces are marked on
terminal block or PCB. Connect cables as picture
shows. Make sure power is off before connecting
ALARM
VI DEO
RS485, AC24V
-17-
6. Set dome ID, baud rate and protocol.
Set dome ID, bard rate and protocol by configuring
DIP switches (Refer to APPENDIX I).
NOTE: Remove the packing sponge.
7. Lower cover preliminary installation.
Attach the safety chain with a M3 screw as picture
shows.
8. Install black liner and Pan/Tilt Module.
Push the black liner into the two tabs. Install the
pan/tilt module with two clips, match color of AMP
sockets. Gently push the module upward until
hearing two clicks.
NOTE: Remove the lens cover.
Tab
Bl ack Li ner
9. Install lower cover.
Unscrew the two M4 screws on lower cover ring.
Push up the lower cover into the housing and then
fasten lower cover with two M4 screws.
NOTE: Apply the lube to the O-ring in the case of
outdoor dome
lube
M4 slot
-18-
PENDANT MOUNT
In case of low ceiling height dome can be mounted
directly into the base flange.
1. Mark the mounting position.
Use the bracket base to mark the fastener positions
on ceiling
2. Install base.
Connect wirings through the central hole of the
bracket base, and then fix it on ceiling.
NOTE: Put silica gel along the top of bracket base
in the case of outdoor dome.
3. Install suspender.
Connect wirings through the cavity of suspender,
and then turn the threaded pipe head into the
bracket base and fasten the connection with a M5
screw.
NOTE: Apply water-proof tape to the thread and
put silica gel to the suspender as picture shows in
the case of outdoor doom.
4. Release the circuit board.
Unscrew to release the circuit board from
connection base
-19-
5. Install housing.
Connect cables through the top hole of the
housing, and then turn the housing thread pipe
head into suspender and fasten the connection
with two M5 screws
NOTE: Apply water-proof tape to the thread in
the case of outdoor dome. If installation height is
not high enough, mount housing directly into the
base.
Tape
Screw
Tape
Screw
6. Connect cables.
Plug cables into corresponding sockets on circuit
board. Reinstall the circuit board and turn on the
power. The red LED is on if connections are
correct. Turn off the power after checking.
NOTE: Names of the interfaces are marked on
terminal block or PCB. Connect cables as picture
shows. Make sure power is off before connecting.
ALARM
VI DEO
RS485, AC24V
7. Set dome ID, baud rate and protocol.
Set dome ID, bard rate and protocol by configuring
DIP switches (Refer to APPENDIX I).
8. Lower cover preliminary installation.
Attach the safety chain with a M3 nut as picture
shows.
lube
M4 slot
1 / 1

Dante DLC1981 Kasutusjuhend

Kategooria
Turvakaamerad
Tüüp
Kasutusjuhend
See käsiraamat sobib ka

teistes keeltes