Lumineux 430159-BL-MW Kasutusjuhend

Tüüp
Kasutusjuhend
READ THESE INSTRUCTIONS
THOROUGHLY BEFORE
INSTALLATION KEEP THESE
INSTRUCTIONS FOR
FUTURE REFERENCE.
IMPORTANT:
This product must be installed
by a qualifi ed electrician or
competent person, and in
accordance with current building
and IET wiring regulations.
Pebley
Utility Round
3CCT Bulkhead
12W
Warranty
5 YR
Technical Helpline: +44 (0)1507 328031
www.lumineux.co.uk
1 2
5
3
6
on
off
4
Pebley Utility
Bulkhead
INSTALLATION INSTRUCTIONS
Turn off the mains power before performing
inspections, installation, or removal
Verify that the supply voltage is correct by
comparing it with the luminaire label information
It is the installers responsibility to ensure installation
is suitable for the total load of the luminaire(s). The
supply cable, fuses/circuit brakers must be correctly
rated for the electrical load and considering for any
transient inrush currents that may occur
Do not perform insulation strength or resistance
tests on installed luminarie(s) connected
PLEASE READ THESE INSTRUCTIONS
BEFORE INSTALLATION.
WARNING: Risk of electric shock! Isolate
the mains power before proceeding.
on
off
Manby Business Park, Manby, Lincolnshire, LN11 8UT
Lumineux is a B&T Associates Ltd company.
EE
A
G
Light Fitting
Instruction Manual
• Fixings
TOOLS REQUIRED
BOX CONTENTS
• Drill
• Screwdriver
• Cable
This lighting  xture has been properly
packed to avoid damage during
transit. Before commencing with the
installation carefully inspect the
luminaire to con rm there is no
damage. DO NOT INSTALL if any
damage has occurred to the  xture
or any of its components.
Grommet
Geartray
Twist-lock
BESA
IP66
3CCT
1. Remove the four screws securing the diffuser
2. Twist the locking tab to loosen and remove the
geartray.
3. Drill appropriately sized holes through your chosen
mounting points in the base
4. Install grommet to your chosen cable entry and pierce,
making a hole just large enough to make a tight  t
around the incoming mains cable. Carefully thread
cable through grommet and secure  tting in place
5. Wire as per diagram (5). Select colour temperature
(Please see overleaf for instructions on how to set
all sensor versions and emergency)
6. Replace the geartray and twist the locking tab to
secure in place, then re t the diffuser and
re-connect the mains supply
Electrical connection wiring
3CCT Switchable
3000K 4000K 6000K
L - LIVE (SL)
= Brown
- EARTH
= Green/Yellow
N - NEUTRAL
= Blue
NPLSL
ROUTINE TEST RECORD
Type Test Year 1 Year 2 Year 3 Year 4 Year 5
Signed Date Signed Date Signed Date Signed Date Signed Date
Functional 1
Functional 2
Functional 3
Functional 4
Functional 5
Functional 6
Functional 7
Functional 8
Functional 9
Functional 10
Functional 11
3hr Duration 12
Installation Engineers Contact Details: Luminaire Reference / Location
Name: Tel:
Luminaire Details: Full Recharge Duration 24 Hours Emergency Duration 3 Hours Lamp Type LED
Pebley Utility Round 3CCT Bulkhead
Technical Helpline: +44 (0)1507 328031
STEP DIM DRIVER SETTINGS
PEBLEY BULKHEAD DIMENSIONS
* Do not change output current unless instructed or this will void warranty.
This luminaire is warranted for a
period of 5 years from the date of
purchase**. The backup battery
pack in the emergency version
is warranted for a period of 24
months. The warranty could be
invalidated should the light tting
not be installed according to these
instructions, outside the scope of
the specication or the product
has been altered or tampered with
in any way. Please see website for
terms and conditions.
Standard -20 to +40ºC
Emergency 0 to +30ºC
DISPOSAL
WARRANTY
PRODUCT TEMP SPECIFICATION
Revision 3.2 - OCTOBER 2022
Disassembly instructions for end of
life disposal available on website.
Disposal of Electronic Equipment
WEEE Directive 2002/96/EC This
product falls within the scope of
the Waste Electrical & Electronic
Equipment Directive (WEEE), which
means the product should not be
disposed of as normal household
waste. Please recycle where
facilities exist or check with your
Local Authority. RoHS – All
components and materials used in
this product are RoHS 2002/95/EC
compliant.
Specications may change from time
to time. The information contained
in this leaet is for guidance only
and should not be considered as
always accurate and should be
treated as not representative.
Part No. Description Watts L (mm) W (mm) H (mm) Weight
430159-
WH
Pebley
Round
Bulkhead
12W
300 300 92
0.7Kg
430159-
BL
Pebley
Round
Bulkhead
12W
300 300 92
0.7Kg
This product contains a light source of energy efciency Class E.
** Please see our website for more detailed information on warranty.
L
W H
MICROWAVE SENSOR SETTINGS
Detection Range: This determines the effective range of the motion.
Note that reducing the sensitivity will also narrow the detection range.
Hold Time Duration: This determines the time the tting remains at
100% illumination following motion detection.
Daylight Setting: This setting holds off the 100% light output should
there be sufcient daylight.
STANDARD ON/OFF SENSOR
DETECTION AREA
1
I ON 100%
II - 50%
HOLD TIME
2 3
I ON ON 5S
II ON - 90S
III - ON 3min
IV - - 10min
DAYLIGHT SENSOR
4 5
I ON ON Disable
II ON - 30 Lux
III - ON 15 Lux
IV - - 5 Lux
STAND-BY
DIM LEVEL
8
I ON 10%
II _ 25%
* OUTPUT CURRENT
S1 S2 S3
450mA ON ON ON
400mA ON - ON
380mA - - ON
350mA - ON -
320mA ON - -
300mA - - -
STAND-BY PERIOD
6 7
I ON ON 0s
II ON - 30s
III - ON 10min
IV - - +∞
DETECTION AREA
1 2 3
I ON ON ON 100%
II - ON ON 75%
III ON - ON 50%
IV - - ON 25%
V - - - 10%
DAYLIGHT SENSOR
7 8 9
I ON ON ON 2Lux
II ON ON - 10Lux
III - ON - 25Lux
IV ON - - 50Lux
V - - - Disable
HOLD TIME
4 5 6
I ON ON ON 5s
II - ON ON 30s
III ON - ON 90s
IV - - ON 3min
V ON ON - 20min
VI - - - 30min
1. Connect incoming earth cable to ‘Earth’ terminal on connector block.
2. Connect incoming neutral cable to ‘Neutral’ terminal on connector block.
3. For the emergency unit to work correctly, please ensure that an
uninterrupted permanent live feed is present and is connected directly
to the ‘Permanent Live’ terminal of the mains terminal block. Please
ensure there are no switches, PIRs etc within the permanent live feed,
constant switching of the emergency pack could result in premature
battery failure.
4. Connect incoming switched live cable to the terminal marked
“Switched Live”
NOTE: If there is no switch live feed and the unit has a microwave sensor,
simply bridge across from the “Permanent Live” to the Switch Live” on the
mains terminal block.
5. There should be a loose ying lead connected to the battery. This needs
to be attached to the ying lead from the emergency control unit.
6. Following power up the green LED indicator should illuminate to indicate
charging. If power to the unit is disrupted or isolated, the unit indicating
green LED will switch off, triggering the emergency LEDs to illuminate.
7. Please allow 24 hours charge before rst emergency test.
Wiring instructions for units equipped
an with EMERGENCY function
Emergency lighting luminaries must be installed and maintained in
accordance with the emergency lighting standard BS 5266-1
EMERGENCY
FITTINGS ONLY.
EARTH
CONNECTION
REQUIRED.
L - LIVE (SL)
= Brown
- EARTH
= Green/Yellow
N - NEUTRAL
= Blue
PL - PERMANENT
LIVE = Black
NPLSL
  • Page 1 1
  • Page 2 2