OPTIONAL TIMER KIT AOPS7433
MO-431
ECN 5507-MA 171201
Installation of Solid State Timer to Oil Furnace TIMER - TP Part No. 350506
1) Turn power off to furnace.
2) Mount timer just above 4 X 4 junction box (within 5”) on side casing of furnace. Use mounting
screw provided.
3) Open junction box and connect 3 short wires as shown on wiring diagram.
4) Connect long black wire to primary control located on junction box on oil burner.
Note: Burner Polarity must be correct.
5) Adjust timer to recommended settings. DOM (sec) 72
DOB (min) 4.0
NOTE: DOM value = Set the arrow on the dial between the 7
th
and 8
th
tick mark on t1. This time
should be approximately 72 seconds (+8/-16 seconds)
DOB value = Set the arrow on the dial between the 5
th
and 6
th
tick mark on t2. This time
should be approximately 4 minutes (±15 seconds)
Confirm timings are set as desired prior to leaving furnace with a stopwatch.
6) Re-establish power and check furnace operation.