•Notwhereambienttemperatures
are likely to exceed 50°C.
•Ifinstalledinakitchenfansmust
not be mounted immediately
above a cooker hob, or eye
level grill.
• Ifinstallinginaroomcontainingafuel
burning device which has a non-balanced
flue, it is the installer’s responsibility to
ensure that there is enough replacement
air to prevent fumes being drawn down
the flue when the fan is operating up
to maximum extract. Refer to Building
Regulations for specific requirements.
• Exhaustairmustnotbedischargedinto
a flue used for exhausting of fumes from
appliances supplied with energy other
than electric. Requirements.
• Notsuitableforuseinpossiblechemical
corrosive atmospheres.
Installation
What the installer will need.
•3mmelectrician’sscrewdriver
andNo.1or2Pozidrive
screwdrivers.
If wall mounting the fan, you will also need:
• A100mmdiameterpreparedhole.
• AnappropriateexternalWallGrilleand
Ø100mmwallsleeveduct.KitRef91232AW.
If ceiling mounting the fan, you will also
need:
• A100mmdiameterpreparedhole.
• Appropriateancillariesfortermination.These
itemsareavailablefromXpelair:
1.3mexibleductingRef:89663AA.Ifthe
ductpassesthroughacoldspaceuse
insulatedductref:89847AA.
2.SotGrilleRef:89742AW.
3.XCT100–CondensationTrap.Ref:
89749AA.Fittedimmediatelyabovethe
fan,thispreventswateringressdueto
condensationformingintheductabove
thefanandrunningdown.
If surface mount wiring the fan, you will
also need:
• MiniaturePVCtrunking16mmwidex8mm
deeptohousethecabletothefan.
Installing the isolating switch
and cables.
Ameansfordisconnectioninall
polesmustbeincorporatedin
thexedwiringinaccordancewithwiring
regulations
• Ifmetalswitchboxesareused,earthing
regulations must be followed.
• Thecross-sectionalareaofthesupplycord
usedshouldberangedfrom1-1.5mm².
• C4S/C44R/C4PS/C4PR–2core,C4TS/
C4TR/C4HTS/C4HTR–3core.
• C4TS/C4TR/C4HTS/C4HTR.Awallor
ceilingOn/Oswitch(withindicatorlight)is
recommended
1. Check that the electrical rating shown
inside the back-plate matches your mains
supply.
2. Check there are no buried pipes or cables
e.g. electricity, gas, water behind the
switch location (in the wall or above the
ceiling). If in doubt, seek professional
advice.
3. Isolate the mains supply.
4.Layinthecablefromtheisolatingswitch
tothefanlocationviatheon/oswitch(if
required).Thismustbehousedinminiature
PVCtrunking.
5.Layinthecablefromtheisolatingswitchto
thepointofconnectiontothemainssupply.
Warning: Do not make any
connections to the electrical
supply at this stage.
6.Installtheisolatingswitchandon/oswitch
(ifrequired).
7.Makeallconnectionswithintheisolating
switchandtheon/oswitch(ifrequired).
Wet Rooms: On/Off switch must
be situated so that it cannot be
touched by persons making use of
the bath or shower.
For Australia Only – C4S /C4R / C4PS /
C4PR
Connectiontothesupplycanbemadebya
exible2-corecablecompletewith3pinplug
forinsertionintoanapproved10AGPOor
directlywiredthroughanapproved10Awall
mountedsurfaceswitchwithatleast3mm
clearancebetweencontacts.
For Australia Only – C4TS / C4TR / C4HTS /
C4HTR
Thesemodelsarepermanentlyconnectedto
thesupplyandoperationiscontrolledbya
remoteswitch.Theyshouldbedirectlywired
tothesupplythroughanapproved10Awall
mountedsurfaceswitchwithatleast3mm
clearancebetweencontacts.
EnglishEnglish