Aquatica Digital Olivia Installation & Care Manual

Tüüp
Installation & Care Manual
www.aquaticabath.com
Olivia
Corner acrylic bathtub
Installation & Care Manual
USA and CANADA
www.aquaticabath.com
P-Trap
(not supplied)
Olivia
Corner acrylic bathtub
Aquatica
®
Freestanding
Bath Installer™
(not supplied)
1½” flanged brass
tube for Aquatica
®
cable-drive and
concealed bath
wastes.
PLEASE NOTE: Parts marked with are supplied as part of Aquatica
®
Freestanding Bath Installer™ Kit (NOT included with bathtub)
57.5”
55.0”
30.0”
55.0”
30.0”
41.75”
22.5”
26.75”
20.0”
16.5”
SIDE ELEVATION
Use “1 1/2” PVC or ABS Female Adapter
(use of PVC or ABS depends on your local or state
plumbing codes) Hub x FIPT
he ABS or PVC female adapter features a hub x female NPT thread
connection and provides a means for adapting a solvent weld
connection to a threaded connection.
Home Depot PART
1 1/2” ABS
Female Adapter
Hub x FIPT
3 Fully tile the bathroom floor and walls behind the bathtub
Olivia
Corner acrylic bathtub
6 & 7
1 Choose appropriate area for bathtub installation
5
i)
Drill bolts through side lip into
fully finished bathroom wall
ii) Silicone seal around the top edges
2 Complete floor plumbing & water supply lines for faucets
i) Use Aquatica
®
Installation Kit
ii) Check Page x for detailed instructions
on how to use the Aquatica Installation kit
Attach the Side Panel
i) Leave 0.5” space between bottom of side panel and bathroom floor.
ii) Fit the top of the panel between fitting and base frame.
iii) Secure in place with fitting bolts.
4 Place tub in position
TYPICAL FREESTANDING BATHTUB INSTALLATION PROCEDURE
Before you start:
Ensure that the floor is even.
The waste-overflow fitting is supplied with the product, however other accessories like the slip joint and
adaptors are not included and must be purchased separately.
Because of the technical features of the product, it should be used only with the supplied waste-overflow
or specific 3rd party models that have been tested and approved by us.
Place the bathtub by raising it up 4” with 4x4 pieces of lumber so you can have access from the bottom
of the bathtub.
The bath must rest on its feet, not the monobloc sides. The feet must be adjusted to compensate for any
floor imperfections and leave minimal gap with floor.
INSTALLATION SEQUENCE
The Olivia™ bathtub is equipped with factory pre-installed overflow system.
The waste pipe/p-trap connection must be made directly to the waste/drain outlet located at the bottom of the tub.
Picture 1-2: the bathtub is leveled via a water level at the intended local installation area.
Picture 3: place the bathtub by raising it up 4” with 4x4 pieces of lumber so you can have access from the bottom of
the bathtub. Important note: during the installation, the bathtub should not be turned on its side to prevent its weight
from deflecting its monobloc sides. This is why it is important to use supports to raise the bathtub above the floor.
This will also provide you with easy access to the internal plumbing parts.
1 2 3
Olivia
Corner acrylic bathtub
www.aquaticabath.com
1½” ABS DWV Hub
x FIPT Female Adapter*
INSTALLATION SEQUENCE continued
Picture 4: the water outlet pipe should be connected.
Picture 5: foot leveling lock nuts are adjusted.
Picture 6: silicone is applied to the feet of the bathtub that stands on the floor.
Picture 7: when the installation is completed, the bathtub is taken down from the supports ( ie 2 x 4x4's).
If necessary, installation is completed by applying silicone at several points between the bottom panel and floor.
Compatible adaptors for adapting a threaded male connection to a solvent weld connection:
Mueller Industries: Part # 05913
Or
Nibco: C4803
http://www.homedepot.com/p/NIBCO-1-1-2-in-PVC-DWV-Hub-x-FIPT-Female-Adapter-C4803HD112/100677994
The adaptor must have the appropriate thread type or it will keep slipping and you will not be able to
get a tight connection!
Olivia
Corner acrylic bathtub
4
5
76
Aquatica
®
Freestanding Bath Installer
(Kit available separately - not included with bathtub)
1
7
8
"
48mm
9
3
8
"
238mm
2"
52mm
1
1
4
"
32mm
4
1
8
"
103mm
6
1
4
"
159mm
1
1
2
"
39mm
1
1
2
"
38mm
8"
203mm
8"
203mm
1
1
2
"
38mm
1 ½ " brass tube for female threaded
stone bath wastes.
1 ½ " flanged brass tube for Aquatica
®
cable-drive and concealed bath wastes.
1
1
2
"
38mm
8"
203mm
8"
203mm
1
1
2
"
38mm
1 ½ " brass tube for female threaded
stone bath wastes.
1 ½ " flanged brass tube for Aquatica
®
cable-drive and concealed bath wastes.
FEATURES
18 Gauge Epoxy coated Metal Deck Flange
Designed to be installed in an 8” joist space
Can be installed with Waterproofing Membrane
(*bronte™ NobleSeal TS Recommended)
CSA Certified for Canadian and US markets
KIT INCLUDES
2 Brass Tailpieces (Fine Thread and Flanged)
Freestanding Bath Installer™ assembly with 1-1/2” DWV ABS tailpiece
Cutting template
INSTALLATION TIPS
Use 6.5” hole saw to cut sub floor (not included).
Cutting template included
Do not cut the brass Tailpiece as this may cause a leak
Secure Deck Flange with 6 screws (not included)
Male Adapter Spg x MIPT - ABS DWV
for Aquatica
®
bath wastes with
Sch40 hub outlet.
Thread: 1 ½ NPSM (1 ½ IPS)
www.aquaticabath.com
INSTALLATION INSTRUCTIONS
Attaches to Freestanding Bath W/O
A. Cut 6-1/2” (16.5 cm) hole into wood sub-floor
(use supplied Cutout Template).
B. Measure and cut ABS Tailpiece as necessary
to ensure a secure connection to P-Trap below.
C. Insert Freestanding Bath Installer™ assembly into floor
opening and connect to Pipe below.
D. Affix to sub-floor with 6 screws (not supplied)
A. Install flooring surface, leaving a 6-1/2” opening to
access Drain.
B. Affix the appropriate brass Tailpiece to the Waste &
Overflow. NOTE: DO NOT CUT THE BRASS TAILPIECE
AS THIS MAY CAUSE A LEAK.
Ensure the measurement between the base of the
Drain and P-Trap will accomodate the Tailpiece.
A. Cut out the Installation Label with a utility knife and
remove to expose the Drain.
B. Apply lubricant (supplied) to the Tailpiece.
C. Position the Tub and brass Tailpiece in-line with the Drain.
D. Carefully lower the tub with the installed brass Tailpiece
into the Red Collar in Drain assembly. Ensure Tailpiece is
fully engaged with Seal.
Aquatica
®
Freestanding Bath Installer
(Kit available separately - not included with bathtub)
1
2
3
IMPORTANT: Do not remove Installation Label until Step 3.
DO NOT CUT THE SUPPLIED BRASS TAILPIECE. Doing so may cause a leak.
Disassembling the drain or cutting the Tailpiece will void the warranty.
www.aquaticabath.com
LV
Pind vajab puhastamist ja hooldust. Siledale pinnale ei kogune
mustus kergelt.
Kasuta pehmet kangast, pesuvahendit ja vett regulaarseks
hoolduseks. Puhasta kuiva kangaga.
Väldi abrasiive või lahusteid, mis võiks pinda kahjustada.
Mitte korrektes hoolduse käigus tekitatud vigastused
ei kuulu garantii alla.
EST
Hooldus juhend
Hooldus juhend
LV/LT/RU/PL/EST/EN/DE/FR/IT
max. 60°C
PAA Ltd.,
Unijas street 12A, Riga, Latvia
13
EN 14516
CL1
CA-DA
PAA-BT-SILKS-19/2013
Maintenance Instructions
The smooth surface of your Aquatica
®
Acrylic
Bathtub accumulates hardly any dirt, and can be
maintained by simply cleaning with a soft cloth,
using a mild detergent in water, then wiping over
with a dry cloth.
Avoid using abrasive cleansers or solvents,
which will cause damage to the surface. Damage
caused by use of these products, or any other
inappropriate treatment, is not covered by our
guarantee.
Инструкция по уходу
Поверхность легко чистится. За счет
гладкости грязь к ней не прилипает. Для
регулярного ухода используйте мягкую
ткань, мыльный раствор и воду. После
чистки вытирайте поверхность сухой тканью,
которая хорошо впитывает влагу.
Не используйте губки с абразивной
поверхностью и агрессивные растворители,
которые могут повредить ванну.
Повреждения, возникшие вследствие
неправильного ухода, не покрываются
гарантией.
Installation & Entretien
Cette surface est facile à entretenir et à
nettoyer. Sa surface particulièrement lisse, ne
retiens que très peu la saleté. Un entretien
quotidien nécessite simplement l’utilisation
d’un chiffon doux, de l’eau et un peu de savon.
Essuyer avec un chiffon sec. L’utilisation de
détergents ou de solvants endommageraient
cette surface. Les dommages resultants d’un
traitement non conforme effectué par l’utilisateur
sont exclus de la garantie que nous offrons.
Manuale per il corretto mantenimento
La superficie necessita di pulizia ed accorgimenti
per il corretto mantenimento. Una superficie
liscia non accumula lo sporco. Usare una
spugnetta con del detergente non aggressivo
per una pulizia regolare. Asciugare con un
panno. Evitare l’uso di solventi o materiali
abrasivi: potrebbero rovinare la superficie.
Un danno causato da trattamento inappropriato
non verra’ coperto dalla garanzia.
Instrucciones para la correcta manutención
La superficie debe de ser limpiada y
adecuadamente mantenida. Una superficie lisa
no acumula suciedad.
Utilice una esponja con un detergente suave
para la limpieza diaria. Seque con un paño.
No utilice disolventes o materiales abrasivos ya
que podrían dañar la superficie.
Los daños causados por el tratamiento
inadecuado no serán cubiertos por la garantía.
Olivia
- Maintenance Instructions
Olivia
- Инструкция по уходу
Olivia
- Installation & Entretien
Olivia
- Manuale per il corretto mantenimento
Olivia
- Instrucciones para la correcta manutención
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8

Aquatica Digital Olivia Installation & Care Manual

Tüüp
Installation & Care Manual

teistes keeltes