bel Digital Audio BM-AV3S Kasutusjuhend

Tüüp
Kasutusjuhend
BM-AV3S
A/V monitor system
Users Guide Version 1.4 2/10/2009
BEL DIGITAL AUDIO BM-AV3S
BEL (Digital Audio) Ltd. has made every effort to ensure the accuracy of information contained within
this document which is nevertheless supplied for information purposes only and does not constitute
any form of warranty or guarantee.
All trademarks acknowledged.
The information in this document is subject to change without notice.
Bel (Digital Audio) Ltd.
Unit 3
Horwood Court
Bletchley
Milton Keynes
Bucks
MK11RD
UK
Tel: +44 ( 0) 1908 641063
Web: www.beldigital.com
© 2009 BEL (Digital Audio) Ltd
BEL DIGITAL AUDIO BM-AV3S
© 2009 BEL (Digital Audio) Ltd
C
C
o
o
n
n
t
t
e
e
n
n
t
t
s
s
INTRODUCTION 1
Main features 1
OPERATION 3
S
ELECTING SOURCES 3
B
ARGRAPH SCALES 4
INSTALLATION 5
CONNECTOR I/O 5
RS232 Host interface connector pinout 6
CONFIGURATION 7
Adjusting analog input level 8
Adjusting audio monitor output level 9
Adjusting bargraph break-points and ballistics 10
Inserting bargraph graticules 13
USING MONITORMX SOFTWARE 14
Main Features 14
MONITORMX SOFTWARE OPERATION 15
Running MonitorMx software for the first time 15
Viewing connected frames 15
Configuring alarms 16
Source selection 17
Meter characteristics 17
Disabling local control 17
MONITORMX SOFTWARE INSTALLATION 18
Minimum pre-requisites: 18
Serial cable 18
BM-AV3 SERIAL PROTOCOL 20
OVERVIEW 20
Frame format 20
COMMANDS 22
DATA FORMATS 23
PROBLEM SOLVING 28
BEL DIGITAL AUDIO BM-AV3S
© 2009 BEL (Digital Audio) Ltd
Sample problems and their solutions 29
SPECIFICATIONS 30
BEL DIGITAL AUDIO BM-AV3S Introduction
© 2009 BEL (Digital Audio) Ltd 1 Version 1.0.4
I
I
n
n
t
t
r
r
o
o
d
d
u
u
c
c
t
t
i
i
o
o
n
n
The BM-AV3S is a professional audio and video monitor system housed in a 3U rack.
The unit features two speakers, a high quality seven inch TFT video display and an analogue
line output. Audio input signals can be in the form of analog, AES (SPDIF) and SDI
embedded data. The BM-AV3S accepts audio inputs in groups of 4 channels from the
selected source and can direct any two from these to the speakers. Video input signals can
be selected from a pair of SDI inputs or an analog composite input.
Main features
2 x SDI and 1 x composite video inputs with seven inch TFT colour video display
Auto PAL/NTSC detection
SDI embedded (groups 1 – 4), 2 x AES and 2 x analog audio input pairs
Option for balanced XLR or unbalanced BNC digital audio I/O
High-quality, high SPL audio reproduction with soft limiting
4 x tri-colour bargraphs with six standard scales and ballistics, adjustable colour
transition points and peak-hold facility
Line level analog audio output of sources directed to loudspeakers
Audio follow video facility
Selected SDI source converted to analog composite video for convenient monitoring
Headphone connector with speaker mute
Individually user-calibrated audio level inputs/outputs and metering
Windows GUI and separate RS232 protocol for remote control of all alarm functions
and audio/video switching
BEL DIGITAL AUDIO BM-AV3S Introduction
The BEL Digital BM-AV3S
All audio inputs are converted to 24 bit digital form and AES inputs are re-sampled using
sample rate converters where necessary at an internally generated 48 kHz. If embedded
audio from a serial digital video input is selected, the sampling clock recovered from this is
used instead.
The audio source switch selects which audio source is available to the speaker selectors and
bargraphs.
The left and right speaker switches select which of the currently selected four audio channels
is available at the speakers after three stages of analog processing.
The selected audio is first passed through factory preset equalization filters. Then electronic
level control is then applied with the balance and volume knobs providing control voltages.
Finally a soft limiter is used to protect the speakers. The headphone output is taken before
the limiters and mutes the speakers when used.
A soft mute is applied to the audio when any select switches are used to reduce glitches.
© 2009 BEL (Digital Audio) Ltd 2 Version 1.04
BEL DIGITAL AUDIO BM-AV3S Operation
© 2009 BEL (Digital Audio) Ltd 3 Version 1.04
O
O
p
p
e
e
r
r
a
a
t
t
i
i
o
o
n
n
The front panel user interface consists of 6 rotary controls, a menu button, a TFT display and
four bargraphs. In addition there is a headphone output, two LEDs for sustained anti-phase,
and five status LEDS.
The BM-AV3S front control panel
Selecting sources
The audio source switch selects which group of audio sources is available to the speaker
selectors and bargraphs. The possible choices are analog, AES A + B, embedded groups 1
to 4 from either SDI1 or SDI2 or Audio Follow Video (AFV). The video source switch
determines which SDI input audio is de-embedded from.
The AFV position establishes the follow mode, where the audio is automatically selected
depending on the position of the video source switch. For example, composite video
selection will cause analog audio to be selected, SD1 will allow group 1 of the SDI1 serial
digital input to be monitored and SD2 will monitor group 1 from the SDI2 serial digital video
input.
The REM or remote position of the video source switch forces BM-AV3S to be controlled
from the serial port. Any serial commands will then take precedence over the front control
panel.
The image displayed on the TFT can be adjusted by pressing the menu button and then
following the on screen instructions.
Note:
If an SDI video source is selected using the video source switch, that input will provide
de-embedded audio. If the video source switch is in the composite position (or REM with
no active remote video selection) and an SDI audio source is selected, then audio
groups 1 to 4 are taken from SDI1.
BEL DIGITAL AUDIO BM-AV3S Operation
Bargraph scales
The following bargraph ballistics may be selected using internal switches.
Scale type
Range Attack Fallback
AES/EBU: 60 dB (0 to -60 dB) 1ms 1.5 Sec per 20 dB decay
DIN PPM: 55 dB (+5 to -50 dB) 10 ms 1.5 Sec per 20 dB decay
VU: 23 dB (+3 to -20 dB) 300 ms 300 ms
BBC PPM: +12 to-12 dB - mark 7 to 1 10 ms 2.85 Sec - mark 7 to 1
VU EXT: 80 dB (+20 to -60 dB) 300 ms 300 ms
NORDIC: 54 dB (+12 to -42 dB) 5 ms 1.7 Sec per 20 dB decay
BM-AV3S scale ballistics
Stick-on scale graticules, which may be applied to the space between the front-panel
bargraphs, are supplied with the machine.
BM-AV3S scale graticules
Note:
Bargraph colour transition points and peak hold decay may also be adjusted
internally.
Refer to the Configuration chapter for switch settings and graticule fitting
instructions.
© 2009 BEL (Digital Audio) Ltd 4 Version 1.04
BEL DIGITAL AUDIO BM-AV3S Installation
© 2009 BEL (Digital Audio) Ltd 5 Version 1.04
I
I
n
n
s
s
t
t
a
a
l
l
l
l
a
a
t
t
i
i
o
o
n
n
The BM-AV3S 3U frame may be installed in 19 inch bays with 300 mm depth including
typical cable and connector depth. Ventilation is by natural convection and there are vents at
each side and on the top and bottom covers of the unit.
Frames may be installed into bays, providing airflow through these vents is not impeded.
Connector I/O
All connections, with the exception of the headphone socket, are provided on the rear panel
of the frame. Video inputs and outputs use BNC connectors and all data connectors use 9
way ‘D’ type connectors.
The BM-AV3S balanced audio version rear view
Digital audio I/O may be supported with either XLR connectors for balanced audio or BNCs
for unbalanced audio, depending on the BM-AV3S version.
BEL DIGITAL AUDIO BM-AV3S Installation
RS232 Host interface connector pinout
Connector type: 9 way D female
Speed: 9600 bps
Format: 8 bit, no parity, 2 stop bits
Pin
Description
1
Not connected
2
Rx (from host)
3
Tx (to host)
4
Not connected
5
GND
6
Not connected
7
Not connected
8
Not connected
9
Not connected
Note:
A null-modem lead will be required to interface to a PC. See the MonitorMx
software chapter for more details.
© 2009 BEL (Digital Audio) Ltd 6 Version 1.04
BEL DIGITAL AUDIO BM-AV3S Configuration
© 2009 BEL (Digital Audio) Ltd 7 Version 1.04
C
C
o
o
n
n
f
f
i
i
g
g
u
u
r
r
a
a
t
t
i
i
o
o
n
n
Access to BM-AV3S internal adjustments is obtained with the top removed.
BM-AV3S internal adjustments
The following adjustments may be made:
Monitor output level – SW3/potentiometers main board
Analog input level – SW4 and SW5/potentiometers main board
Bargraph settings – SW1 and SW2 main board, near power supply
Warning:
Configuration instructions are for trained personnel. To avoid risk of dangerous
electric shock, do not remove any covers or carry out adjustments unless qualified
to do so.
BEL DIGITAL AUDIO BM-AV3S Configuration
Adjusting analog input level
In the following tables, ON is obtained with a switch lever in the DOWN position. The
adjustments are located on the main board under the output sub-board.
Analog input adjustments – 0 dB setting shown
SW4
Anlg
Input
Setting when ON
1
1 0 dB (0 dBu in = 0 on analog scale)
2
1 4 dB (+4 dBu in = 0 on analog scale)
3
1 8 dB (+8 dBu in = 0 on analog scale)
4
1 Variable – adjacent pot* –10 to +12 dB
5
2 0 dB (0 dBu in = 0 on analog scale)
6
2 4 dB (+4 dBu in = 0 on analog scale)
7
2 8 dB (+8 dBu in = 0 on analog scale)
8
2 Variable – adjacent pot* –10 to +12 dB
SW5
Anlg
Input
Setting when ON
1
3 0 dB (0 dBu in = 0 on analog scale)
2
3 4 dB (+4 dBu in = 0 on analog scale)
3
3 8 dB (+8 dBu in = 0 on analog scale)
4
3 Variable – adjacent pot* –10 to +12 dB
5
4 0 dB (0 dBu in = 0 on analog scale)
6
4 4 dB (+4 dBu in = 0 on analog scale)
7
4 8 dB (+8 dBu in = 0 on analog scale)
8
4 Variable – adjacent pot* -10 to +12 dB
Note:
It is intended that only one switch lever is set ON for each analog input.
The ON position is obtained with a switch lever in the direction of the arrow
(downward in the above drawing).
*Clockwise rotation increases gain.
© 2009 BEL (Digital Audio) Ltd 8 Version 1.04
BEL DIGITAL AUDIO BM-AV3S Configuration
Adjusting audio monitor output level
In the following tables, ON is obtained with a switch lever in the DOWN position. The
adjustments are located on the main board under the output sub-board.
Analog monitor output adjustments – 0 dB setting shown
SW3
Monitor
Output
Setting when ON
1
Left 0 dB (0 on analog scale = 0 dBu on output)
2
Left 4 dB (0 on analog scale = +4 dBu on output)
3
Left 8 dB(0 on analog scale = +8 dBu on output)
4
Left Variable – adjacent pot* 0 to +12 dB
5
Right 0 dB (0 on analog scale = 0 dBu on output)
6
Right 4 dB (0 on analog scale = +4 dBu on output)
7
Right 8 dB(0 on analog scale = +8 dBu on output)
8
Right Variable – adjacent pot* 0 to +12 dB
Note:
It is intended that only one switch lever is set to ON for each monitor output.
The ON position is obtained with a switch lever in the direction of the arrow
(downward in the above drawing).
*Clockwise rotation increases gain.
© 2009 BEL (Digital Audio) Ltd 9 Version 1.04
BEL DIGITAL AUDIO BM-AV3S Configuration
Adjusting bargraph break-points and ballistics
The adjustments, SW1 and SW2 are located near the power supply.
BM-AV3S bargraph adjustments
SW1-8
AES to analog adjust
OFF
ON
-18 dBFS = 0 on analog scale
-20 dBFS = 0 on analog scale
The –18 dB and –20 dB settings define the correspondence between AES input level and the
0 mark on an analog scale. This allows analog scales to be used with digital signals.
Note:
When digital inputs are used with an analogue scale the line outputs will be less than
that indicated on the meters since the digital to analogue converters clip at +15 dB.
The effective loss is -3 dB when the 18 dB position is selected and -5 dB when the 20
dB position is selected.
SW1-7 SW1-6
Peak hold decay
OFF OFF None (Off)
OFF ON 3 seconds
ON OFF 7 seconds
ON ON Indefinite
SW1-5 SW1-4 SW1-3
Scale type
OFF OFF OFF AES
OFF OFF ON DIN
OFF ON OFF VU
OFF ON ON BBC
ON OFF OFF Extended VU
ON OFF ON NORDIC
ON ON OFF No scale
ON ON ON No scale
Note:
The OFF position is obtained with a switch lever in the direction of the arrow, (to the
right in the above drawing).
© 2009 BEL (Digital Audio) Ltd 10 Version 1.04
BEL DIGITAL AUDIO BM-AV3S Configuration
Each bargraph has 53 tri-colour segments. The top and bottom segments are reserved
leaving 51. Up to 31 of the remaining top most segments may be coloured red. Up to 31 of
segments from the end of the red zone downward may be coloured amber. The remaining
segments (if any) are always green.
Choosing how many segments are coloured red from the top of the bargraph sets the ‘red
zone’. Select from none to 31 using SW1-2, SW1-1, SW2-8, SW2-7 and SW2-6 as follows:
SW1-2 SW1-1 SW2-8 SW2-7 SW2-6
Segment from bargraph top
OFF OFF OFF OFF OFF None
OFF OFF OFF OFF ON 1
OFF OFF OFF ON OFF 2
OFF OFF OFF ON ON 3
OFF OFF ON OFF OFF 4
OFF OFF ON OFF ON 5
OFF OFF ON ON OFF 6
OFF OFF ON ON ON 7
OFF ON OFF OFF OFF 8
OFF ON OFF OFF ON 9
OFF ON OFF ON OFF 10
OFF ON OFF ON ON 11
OFF ON ON OFF OFF 12
OFF ON ON OFF ON 13
OFF ON ON ON OFF 14
OFF ON ON ON ON 15
ON OFF OFF OFF OFF 16
ON OFF OFF OFF ON 17
ON OFF OFF ON OFF 18
ON OFF OFF ON ON 19
ON OFF ON OFF OFF 20
ON OFF ON OFF ON 21
ON OFF ON ON OFF 22
ON OFF ON ON ON 23
ON ON OFF OFF OFF 24
ON ON OFF OFF ON 25
ON ON OFF ON OFF 26
ON ON OFF ON ON 27
ON ON ON OFF OFF 28
ON ON ON OFF ON 29
ON ON ON ON OFF 30
ON ON ON ON ON 31
Note:
It is not possible to set 31 red and 31 amber segments, since there are only 51
segments for level display purposes.
© 2009 BEL (Digital Audio) Ltd 11 Version 1.04
BEL DIGITAL AUDIO BM-AV3S Configuration
Choosing how many segments are coloured amber from the end of ‘red zone’ sets the
‘amber zone’. Select from none to 31 using SW2-5, SW2-4, SW2-3, SW2-2 and SW2-1 as
follows:
SW2-5 SW2-4 SW2-3 SW2-2 SW2-1
Segment from last RED ZONE
OFF OFF OFF OFF OFF None
OFF OFF OFF OFF ON 1
OFF OFF OFF ON OFF 2
OFF OFF OFF ON ON 3
OFF OFF ON OFF OFF 4
OFF OFF ON OFF ON 5
OFF OFF ON ON OFF 6
OFF OFF ON ON ON 7
OFF ON OFF OFF OFF 8
OFF ON OFF OFF ON 9
OFF ON OFF ON OFF 10
OFF ON OFF ON ON 11
OFF ON ON OFF OFF 12
OFF ON ON OFF ON 13
OFF ON ON ON OFF 14
OFF ON ON ON ON 15
ON OFF OFF OFF OFF 16
ON OFF OFF OFF ON 17
ON OFF OFF ON OFF 18
ON OFF OFF ON ON 19
ON OFF ON OFF OFF 20
ON OFF ON OFF ON 21
ON OFF ON ON OFF 22
ON OFF ON ON ON 23
ON ON OFF OFF OFF 24
ON ON OFF OFF ON 25
ON ON OFF ON OFF 26
ON ON OFF ON ON 27
ON ON ON OFF OFF 28
ON ON ON OFF ON 29
ON ON ON ON OFF 30
ON ON ON ON ON 31
© 2009 BEL (Digital Audio) Ltd 12 Version 1.04
BEL DIGITAL AUDIO BM-AV3S Configuration
Inserting bargraph graticules
The following bargraph scale graticules are supplied with each BM-AV3S:
BM-AV3S scale graticules
To apply a graticule proceed as follows:
peel back the protective backing from the chosen graticule
apply the graticule to the space between a pair of bargraphs
repeat the process for the other bargraph graticule position
ensure that the bargraph setting matches the graticule
adjust the colour transitions and peak hold decay as desired
© 2009 BEL (Digital Audio) Ltd 13 Version 1.04
BEL DIGITAL AUDIO BM-AV3S Using MonitorMx software
© 2009 BEL (Digital Audio) Ltd 14 Version 1.04
U
U
s
s
i
i
n
n
g
g
M
M
o
o
n
n
i
i
t
t
o
o
r
r
M
M
x
x
s
s
o
o
f
f
t
t
w
w
a
a
r
r
e
e
The MonitorMx remote control and status software has been provided to ease the task of
operating and monitoring one or more BM-AV3 units from remote locations.
Main Features
Fifteen alarm categories
Signal presence
Support for multiple BM-AV3 units
Automatic model detection and custom unit names
Reads selected meter ballistics
Full editing of scale transition points and peak hold characteristics
Visual and aural alarms
Individual and system alarm reset
Disable option for local controls
The MonitorMx software will run on Windows 98 Second Edition, Windows NT4. Windows
2000 and XP. It will not run on Windows 95 or Windows 98 First Edition.
BEL DIGITAL AUDIO BM-AV3S Using MonitorMx software
MonitorMx software operation
The MonitorMx application provides monitoring of video and audio alarm status for any local
BM-AV3 frame or multiple-frame system.
MonitorMX main screen
Running MonitorMx software for the first time
The MonitorMx software will search automatically for BM-AV3 frames connected to the serial
ports of the PC the software is running on when the application loads. The Alarms Present
indicator will illuminate red if any of the connected frames are generating alarms. Individual
alarms and alarm configuration will only be shown for selected frames.
MonitorMx will not interrogate or connect to frames on a network.
Viewing connected frames
To view connected frames use the unit select box or select List Devices under the view
menu.
© 2009 BEL (Digital Audio) Ltd 15 Version 1.04
BEL DIGITAL AUDIO BM-AV3S Using MonitorMx software
Configuring alarms
To enable alarms on a selected BM-AV3 frame, check the alarm categories at the left of the
main screen. Toggle inverts the selection. If an alarm is generated the associated virtual LED
will change from green to red and will flash if the Flashing box has been checked. If PC
Sounder has been checked an audio alert will also be sent to a sound card and any
connected speakers if fitted.
System alarms
The Systems Alarms command under the View menu will bring up the systems alarms
window.
The MonitorMX system alarms
System alarms are alarms generated by any connected frame. Controls are provided to reset
alarms from all frames and to enable visual alarm flashing and audible alerts for alarms
generated from any connected frames.
Resetting alarms
Alarms are not automatically cancelled when a monitored signal is restored to normal. To
cancel alarms click on a Reset button for an individual frame or for all frames using the Reset
button in the Systems Alarms window.
Muting alarms
An audio alert in the form of a .wav file can be sent to any sound card and connected
speakers. Mute the alarm by un-checking the PC Sounder box for an individual frame or for
all frames using the Systems Alarms window.
Notes:
Un-checking the PC Sounder box does not affect audible alarms on any BM-AV3
frame(s).
The selective SET function of the front control panel is not required, since any alarm may
be selected individually.
© 2009 BEL (Digital Audio) Ltd 16 Version 1.04
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36

bel Digital Audio BM-AV3S Kasutusjuhend

Tüüp
Kasutusjuhend

teistes keeltes