Congratulations on your purchase and welcome to Philips AVENT! To
fully benet from the support that Philips AVENT offers, register your
product at www.philips.com/welcome.
The Philips AVENT Digital Thermometer Set accurately and conveniently
measures your baby’s body temperature orally, axially and rectally. The
regular soother and the soother thermometer are suitable for use with
children aged 0-12 months. The digital exible-tip thermometer is suitable
for children and adults of all ages.
The unique combination of a soother thermometer and a digital, exible-
tip thermometer offers you the choice of adapting the temperature
measurement method to suit your baby.
The storage box contains three items:
- A soother thermometer to reliably measure your baby’s temperature.
It is very convenient to use and comfortable for your baby.
- A regular Freeow soother to let your baby get used to the shape.
- A digital exible-tip thermometer to measure your baby’s body
temperature axially or rectally if you want additional reassurance.
Make sure you follow the safety guidelines in chapter ‘Important’ when
using these items so that you do not expose your child to any risk.
Use the soother thermometer to obtain a temperature indication. Use
the exible-tip thermometer to determine the actual body temperature.
If in any doubt, consult your doctor.


- The symbols on the thermometers have the following meaning:
1 This symbol indicates that you have to read the user manual carefully
before you use the appliance. Save the user manual for future
reference (Fig. 1).
2 This symbol is to identify a type BF applied part complying with
IEC60601-1 (Fig. 2).

- Never attach ribbons or cords to a soother, your child may be
strangled by them.

- Inspect carefully before each use, especially when the child has teeth.
Pull the soother in all directions. Throw away at the rst signs of
damage or weakness.
- Do not store a soother in direct sunlight or near a source of heat, or
store it in disinfectant (‘sterilising solution’) for longer than
recommended, as this may weaken the teat.
- Keep the removable protection cap of the teat away from children to
avoid suffocation.
- Before rst use, place in boiling water for 5 minutes, allow to cool,
and squeeze out any trapped water from the soother. This is to
ensure hygiene.
- Clean before each use.
- Never dip the teat in sweet substances or medication. Your child may
get tooth decay if you do.
- Replace the soother after 4 weeks of use, for safety and hygiene
reasons.
- In the event that the soother becomes lodged in the mouth, DO
NOT PANIC; it cannot be swallowed and is designed to cope with
such an event. Remove from the mouth with care, as gently as
possible.
- Always use this product under adult supervision. Keep in a dry
covered container. Soothers and caps are suitable for all commonly
used forms of sterilisation. Wash your hands thoroughly and ensure
surfaces are clean before contact with sterilised components.
- Expose the handles of night-time soothers to light before use.
- The soother can be cleaned by washing with warm water.
- DO NOT use abrasive cleaning agents or anti-bacterial cleaners on
the soothers. Excessive combinations of detergents may eventually
cause plastic components to crack. Should this occur, replace your
soother immediately.
- DO NOT sterilise the display case.
- For further advice on cleaning, see chapter ‘Cleaning’.

- Do not immerse the measurement unit of the soother thermometer
in water or any other liquid. Never sterilise or boil the measurement
unit.
 7
- Never leave your child when you are measuring its temperature with
the soother thermometer or the exible-tip thermometer.
- The thermometers are not intended for use by persons (including
children) with reduced physical, sensory or mental capabilities, or lack
of experience and knowledge, unless they have been given
supervision or instruction concerning use of the thermometers by a
person responsible for their safety.
- Children should be supervised to ensure that they do not play with
the thermometers.
- Never use the soother thermometer measurement unit separately to
avoid injury.
- Never use the soother thermometer as a regular soother.
- Battery compartment covers must be replaced properly if removed. If
loose, they may choke your child.

- Do not drop the thermometers or expose them to shocks.
- Do not bend or disassemble the measurement unit of the
soother thermometer or the tip of the exible-tip thermometer
- Do not use the thermometer if the display shows the battery symbol.
This means that the battery is low and the measurements will be
inaccurate.
- Only use these thermometers to measure human body
temperatures.
- When not in use, store the soother, the soother thermometer and
the exible-tip thermometer in the storage box supplied.
- Do not use this Philips AVENT soother thermometer in combination
with parts of the old Philips soother thermometer (SCH530).

These Philips AVENT thermometers comply with all standards regarding
electromagnetic elds (EMF). If handled properly and according to the
instructions in this user manual, the thermometers are safe to use based
on scientic evidence available today.
8

Clean the soother, soother thermometer and the exible-tip
thermometer before rst use. See chapter ‘Cleaning’.


The most convenient way to measure your baby’s temperature is to use
the soother thermometer according to this user manual. This method
gives a reliable indication. If you need additional reassurance (for example
if the rst measured temperature is above 38°C), you can then use the
digital exible-tip thermometer to take an axial (underarm) or a rectal
(anal) measurement.
Note: Oral measurements are usually 0.5 to 1°C lower than the actual body
temperature.

The temperature of a child is normally between 36.5 and 37.5°C.
However, you have to keep in mind that a child’s temperature varies
depending on age, activity, time of day, etc. Also remember that some
illnesses do not have high temperature as a symptom.Temperature
measurement should not be a substitute for consulting your physician.
When reporting your child’s temperature to a professional, state the
measurement method.

The most convenient way to measure your baby’s temperature is to use
the soother thermometer. This is also the most comfortable method for
the baby.
Do not use the soother thermometer for 30 minutes after the baby
has had hot or cold drinks, as this causes an inaccurate measurement.

 9
1 Check if the measurement unit of the soother thermometer is
rmly attached to the soother (i.e. turned completely to the closed
lock position).
If the measurement unit is not rmly attached to the soother, the
measurement may be inaccurate and the measurement unit
may become a suffocation hazard.
2 Place the soother in the baby’s mouth for approx. 3 minutes to let
the thermometer warm up.
If you do not do this, the measured temperature may be inaccurate.
3 Press the on/off button I to switch on the thermometer.
Note: You can either press the on/off button while the soother is still in your
baby’s mouth, or you can remove the soother, press the on/off button and
place the soother back into your baby’s mouth.
4 Leave the soother in the baby’s mouth until the thermometer
beeps.
See section ‘Audible signals’ at the end of this chapter for the meaning of
the beeps.
, The display now shows the measured temperature and the °C
indication lights up continuously.
Note: If for some reason the temperature cannot be measured, the display
shows ‘Lo’ or ‘Hi’. This means that the temperature is outside the temperature
range. Switch off the thermometer, check if it is correctly positioned and
switch it on again to restart the measurement.
5 Remove the soother thermometer from the baby’s mouth.
Do not leave the child alone with the soother thermometer.
6 Press the on/off button I to switch off the thermometer.
Note: Switch off thermometer after use to save battery power. If you do not
switch off the thermometer, it switches off automatically: after 1 minute if
the temperature measured is <32°C; or after 10 minutes if the temperature
measured is >32°C.
10

Do not insert the exible-tip thermometer into the ear or nose.
The soother thermometer is just as accurate as the digital exible-tip
thermometer and is more convenient to use. However, because rectal
measurement is inherently more accurate than oral measurement, the
digital exible-tip thermometer gives you an opportunity to reassure
yourself.
For a rectal measurement of a baby’s temperature, proceed as follows:
1 Remove the protection cap from the digital exible-tip
thermometer.
Make sure that the metal probe of the exible tip is still rmly attached to
the thermometer.
Tip: If available, use special plastic hygienic covers to cover the tip of the
thermometer (these are available from most chemists).
2 Lubricate the tip of the thermometer (or hygienic cover) with a
water-soluble jelly.
Water-soluble jelly is available from most chemists.
Note: Do not use petroleum jelly.
3 Press the on/off button I to switch on the thermometer.
4 Lie the baby on its stomach or its side.
5 With one hand, separate the baby’s buttocks. With the other hand,
gently slide the tip of the thermometer no more than 12mm (1/2
inch) into the rectum. If you detect any resistance, stop immediately.
Hold the baby rmly so that it cannot turn while the thermometer is
inserted.
Never push the exible tip too far into the anus.
6 Keep the thermometer in place until it beeps.
See section ‘Audible signals’ at the end of this chapter for the meaning of
the beeps.
 11
Note: If for some reason the temperature cannot be measured, the display
shows ‘Lo’ or ‘Hi’. This means that the temperature is outside the temperature
range. Switch off the thermometer, check if it is correctly positioned and
switch it on again to restart the measurement.
7 Remove the thermometer and read the display.
8 Press the on/off button I to switch off the thermometer.
Note: Switch off thermometer after use to save battery power. If you do not
switch off the thermometer, it switches off automatically: after 1 minute if the
temperature measured is <32°C; or after 10 minutes if the temperature
measured is >32°C.

For older children and adults, the digital exible-tip thermometer can also
be used to measure temperature orally (in the mouth) or axially (in the
armpit).
Do not use the exible-tip thermometer for oral temperature
measurements on babies.
If the thermometer has been used rectally or in the armpit without
hygienic covers, do not use it for oral measurement anymore for
hygienic reasons, not even after cleaning.

Signal Meaning
10 beeps in 10 seconds Measured temperature is normal
(below 37.8°C)
3 sets of short beeps in 10
seconds
Possible fever (measured temperature
above 37.8°C)
12


Both the soother thermometer and the digital exible-tip thermometer
have a memory function. When the soother thermometer and the digital
exible-tip thermometer are switched on, the display automatically shows
the last measured temperature for approx. 2 seconds. The display then
shows the normal body temperature of 37°C.

Both the soother thermometer and the digital, exible-tip thermometer
have a long-life battery which should last for about 2 to 3 years. If the
display shows a battery symbol, the battery is low. Replace the battery of
the exible-tip thermometer (see chapter ‘Replacing the battery’).
Note: The battery of the soother thermometer cannot be replaced. If the
battery is empty, discard the soother thermometer.

Both the soother thermometer and the digital exible-tip thermometer
switch off automatically: - after 1 min if the temperature measured is
<32°C; - or after 10 min if the temperature measured is >32°C.

Both the soother thermometer and the digital exible-tip thermometer
have an error function. In case of malfunction, the display shows an ‘Err’.
Proceed as follows if this happens:
1 Press the on/off button I to switch off the thermometer.
2 Press the on/off button I to switch on the thermometer again.

Do not use abrasive cleaning agents, anti-bacterial cleaning agents or
chemical solvents. Excessive concentration of cleaning agents may
eventually cause plastic components to crack. Do not use cracked
parts.
 13
Clean the regular soother, the soother thermometer and the exible-tip
thermometer after each use to ensure optimal hygiene.
Be careful not to damage the parts when you clean them.

Before rst use, wash and rinse the soother thoroughly.
Clean the soother before each use.
Before cleaning, always remove the measurement unit from the teat
and shield.
1 Turn the measurement unit 90° anticlockwise with respect to the
shield.
2 Pull the measurement unit straight out of the teat and shield.
Note: Be careful not to bend the tip of the measurement probe.
3 Clean the thermometer measurement unit with a soft damp cloth.
Do not immerse the measurement unit in water.
Do not sterilise or boil the measurement unit.
Do not clean the measurement unit in the dishwasher, in
the microwave or in a microwave steriliser.
4 Sterilise or boil the soother and protection cap (not the
measurement unit!).
The soother and protection cap are suitable for all forms of sterilisation.
Sterilise using a Philips AVENT Steam Steriliser or boil in water for 5
minutes.
If you use a sterilising solution, follow the instructions on the package. Do
not leave the soother in the sterilising solution for longer than
recommended, as this may weaken the teat.
Wash your hands thoroughly and ensure surfaces are clean before
contact with sterilised components.
5 After sterilisation, let the soother cool down for 5 minutes and
squeeze out any trapped water from the teat. This is to ensure
hygiene.
14

1 Align the blocks of the measurement unit with the matching slots
in the back of the shield.
2 Insert the measurement unit into the shield. Make sure that the tip
of the probe goes into the pocket inside the teat. (Fig. 3)
3 Turn the measurement unit 90° clockwise to lock it into position.

Do not sterilise or boil the thermometer.
Do not clean the exible-tip thermometer in the dishwasher, in the
microwave or in a microwave steriliser.
1 Clean the exible-tip thermometer with a soft damp cloth.

Before rst use, wash and rinse the soother thoroughly.
Clean the soother before each use.
1 Sterilise or boil the soother.
The soother and protection cap are suitable for all forms of sterilisation.
Sterilise using a Philips AVENT Steam Steriliser or boil in water for 5
minutes.
If you use a sterilising solution, follow the instructions on the package. Do
not leave the soother in the sterilising solution for longer than
recommended, as this may weaken the teat.
Wash your hands thoroughly and ensure surfaces are clean before
contact with sterilised components.
2 After sterilisation, let the soother cool down for 5 minutes
and squeeze out any trapped water from the teat. This is to
ensure hygiene.

Do not sterilise the storage box.
 15
1 Wipe the storage box with a damp cloth.

You can use the storage box to store the soother, the soother
thermometer and the exible-tip thermometer or to take them with you
when you travel.
1 Put the protection caps on the soother, the soother thermometer
and the exible-tip thermometer after use to keep them clean.
2 Put the soother, the soother thermometer and the exible-tip
thermometer in the storage box.
3 Put the storage box in a safe, dry place away from direct sunlight
and heat sources.

Swallowing a button battery is extremely dangerous.
Batteries may explode if exposed to high temperatures or re.
Never attempt to recharge the battery.
If the display shows a battery symbol, the battery is low.
Replace the battery of the exible-tip thermometer as described below.
Note: The battery of the soother thermometer cannot be replaced. If the
battery is empty, discard the soother thermometer.
1 Remove the battery compartment cover (Fig. 4).
2 Use an insulated probe to remove the battery (e.g. a toothpick).
3 Insert a new battery (LR41) with the + pole facing upwards (Fig. 5).
4 Reattach the battery compartment cover (Fig. 6).
5 Dispose of the empty battery in the proper way (see chapter
‘Environment).
16

- Non-rechargeable batteries contain substances that may pollute the
environment. Do not throw away non-rechargeable batteries with the
normal household waste, but dispose of them at an ofcial collection
point for batteries. Always remove the non-rechargeable batteries
before you discard and hand in the thermometers at an ofcial
collection point (Fig. 7).
- Do not throw away the thermometers with the normal household
waste at the end of their life, but hand them in at an ofcial collection
point for recycling. By doing this, you help to preserve the
environment (Fig. 8).

If you need service or information or if you have a problem, please visit
the Philips AVENT website at www.philips.com/AVENT or contact the
Philips Consumer Care Centre in your country (you nd its phone
number in the worldwide guarantee leaet). If there is no Consumer
Care Centre in your country, go to your local Philips dealer.

Digital exible-tip
thermometer
Soother
thermometer
AVENT
soother
Battery 1.55VDC (LR41) Battery not
replaceable
-
Battery life > 100 operating
hours
> 100 operating
hours
-
Measurement
range
32°C to 42.9°C 32°C to 42.9°C -
Accuracy ± 0.1°C for 35°C
to 42°C range
± 0.1°C for 35°C
to 42°C range
-
 17
Digital exible-tip
thermometer
Soother
thermometer
AVENT
soother
Teat size - Suitable for
newborn babies
Suitable for
newborn
babies
Compliance Conforms to
MDD93/42/EEC
Conforms to
MDD93/42/EEC
Conforms
to EN1400

This chapter lists the questions most frequently asked about the
thermometers. If you cannot nd the answer to your question, contact
the Customer Care Centre in your country.
Question Answer
Do I get a different
temperature reading
with the soother
thermometer than
with the digital
exible-tip
thermometer?
Since oral temperature is slightly lower than
actual body temperature, the soother
thermometer gives a reading that is 0.5 to
1°C lower than that of the exible-tip
thermometer.
What does the battery
symbol on the display
of the thermometers
mean?
If the display shows a battery symbol, the
battery is empty and needs to be replaced.
Only the battery of the exible-tip
thermometer can be replaced. The battery of
the soother thermometer cannot be replaced,
and the soother thermometer must be
discarded when the battery is empty.
18
Question Answer
Can I replace the
batteries of the
thermometers myself?
You can replace the battery of the exible-tip
thermometer yourself. For instructions on
how to replace this battery, see chapter
‘Replacing the battery’. The battery of the
soother thermometer cannot be replaced.
When this battery is empty, the soother
thermometer must be discarded.
What does the ‘Err’
indication on the
display mean?
The ‘Err’ indication can appear on the display
of both the exible-tip thermometer and the
soother thermometer and means that there is
a malfunction. Press the on/off button to
switch off the thermometer, then press the
on/off button again to switch on the
thermometer. Proceed to measure the
temperature as usual.
What does ‘Lo’ or ‘Hi’
on the display mean?
The ‘Lo’or ‘Hi’ indications on the display mean
that the temperature cannot be measured
because the temperature is outside the
temperature range. Press the on/off button to
switch off the thermometer. Check if the
thermometer is correctly positioned. Press
the on/off button again to switch on the
thermometer and restart the measurement.
 19
Question Answer
The thermometer
beeps when it has
nished measuring.
What do these beeps
mean?
When you measure your baby’s temperature,
there are 2 different types of beeps that
sound once the temperature has been
measured. These beeps are the same for
the exible-tip thermometer and for the
soother thermometer. When the
thermometer gives 10 beeps in 10 seconds,
the measured temperature is normal, i.e.
below 37.8°C. When it gives 3 sets of short
beeps in 10 seconds, this indicates possible
fever, i.e. the measured temperature is above
37.8°C.
Can I use honey or
other sweet
substances on the
soother?
Never dip the teat in sweet substances or
medication. Your child may get tooth decay if
you do.
What can I do when
some parts of the
thermometers are
broken (e.g. the
exible tip)?
Do not use the thermometers if any part
of them is cracked. If the thermometers are
damaged or broken, they have to be
discarded.
The thermometers do
not work. What is
wrong?
The batteries of the thermometers may be
empty. For instructions on how to replace the
battery of the exible-tip thermometer, see
chapter ‘Replacing the battery’. The battery of
the soother thermometer cannot be replaced.
When this battery is empty, the soother
thermometer must be discarded.
20
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48
  • Page 49 49
  • Page 50 50
  • Page 51 51
  • Page 52 52
  • Page 53 53
  • Page 54 54
  • Page 55 55
  • Page 56 56
  • Page 57 57
  • Page 58 58
  • Page 59 59
  • Page 60 60
  • Page 61 61
  • Page 62 62
  • Page 63 63
  • Page 64 64
  • Page 65 65
  • Page 66 66
  • Page 67 67
  • Page 68 68
  • Page 69 69
  • Page 70 70
  • Page 71 71
  • Page 72 72
  • Page 73 73
  • Page 74 74
  • Page 75 75
  • Page 76 76
  • Page 77 77
  • Page 78 78
  • Page 79 79
  • Page 80 80
  • Page 81 81
  • Page 82 82
  • Page 83 83
  • Page 84 84
  • Page 85 85
  • Page 86 86
  • Page 87 87
  • Page 88 88
  • Page 89 89
  • Page 90 90
  • Page 91 91
  • Page 92 92
  • Page 93 93
  • Page 94 94
  • Page 95 95
  • Page 96 96
  • Page 97 97
  • Page 98 98
  • Page 99 99
  • Page 100 100
  • Page 101 101
  • Page 102 102
  • Page 103 103
  • Page 104 104
  • Page 105 105
  • Page 106 106
  • Page 107 107
  • Page 108 108
  • Page 109 109
  • Page 110 110
  • Page 111 111
  • Page 112 112
  • Page 113 113
  • Page 114 114
  • Page 115 115
  • Page 116 116
  • Page 117 117
  • Page 118 118
  • Page 119 119
  • Page 120 120
  • Page 121 121
  • Page 122 122
  • Page 123 123
  • Page 124 124
  • Page 125 125
  • Page 126 126
  • Page 127 127
  • Page 128 128
  • Page 129 129
  • Page 130 130
  • Page 131 131
  • Page 132 132
  • Page 133 133
  • Page 134 134
  • Page 135 135
  • Page 136 136
  • Page 137 137
  • Page 138 138
  • Page 139 139
  • Page 140 140
  • Page 141 141
  • Page 142 142
  • Page 143 143
  • Page 144 144

Philips AVENT SCH540/01 Kasutusjuhend

Kategooria
Digitaalsed keretermomeetrid
Tüüp
Kasutusjuhend
See käsiraamat sobib ka