Ensto Building Systems Finland Oy
Ensio Miettisen katu 2, P.O. Box 77
FIN-06101 Porvoo, Finland
Tel. +358 204 76 21
ensto.com
Choosing the installation location
When choosing the installation location pay attention to the following:
• Radar sensor can detect movements through thin wall and glass
• The luminaire must be mounted on a stable foundation which does not vibrate
• Large metal surfaces can aect the size and shape of the detection area
• The mounting distance between sensors should be more than 2m to prevent the sensors
from false-triggering
Technical data
Mains voltage 220-240 VAC, 50/60 Hz
Standby power < 0,3 W
Transmission power < 0,2 mW
Operating frequency 5,8 GHz
Max. external load Capacitive 300VA / Resistive 400W
Warming up time 10 s
Do not dispose of electrical and electronic devices including their accessories with the
household waste.
ENG
SWE Val av monteringsplats
Vid val av monteringsplats ta i beaktande följande:
• Radar detektorn kan eventuellt registrera rörelse genom en tunn vägg och glas
• Armaturen måste monteras på ett stabilt underlag som inte vibrerar
• Stora metallytor kan inverka på storleken och formen av detektionsområdet
• Monteringsavståndet mellan sensorerna borde vara mer än 2m för att förhindra sensorer-
nas feltändning
Tekniska data
Märkspänning 220-240 VAC, 50/60 Hz
Energiförbrukning i standby-läge < 0,3 W
Sändningseffekt < 0,2 mW
Funktionsfrekvens 5,8 GHz
Max. yttre belastning Kapacitiv 300VA / Resistiv 400W
Uppvärmningstid 10 s
Kassera inte elektriska och elektroniska enheter inklusive deras tillbehör med hushållsavfallet.