GB
- 19 -
All 3 LEDs are lit:
The battery is fully charged.
2 or 1 LED(s) are lit:
The battery has an adequate remaining charge.
1 LED blinks:
The battery is empty, recharge the battery.
All LEDs blink:
The battery temperature is too low. Remove the
battery from the equipment, keep it at room tem-
perature for one day. If the fault reoccurs, this me-
ans that the rechargeable battery has undergone
exhaustive discharge and is defective. Remove
the battery from the equipment. Never use or
charge a defective battery.
6. Operation
6.1 Switching between mains-powered mode
and battery-powered mode (Fig. 2)
The following operations are possible in both
mains-powered mode and battery-powered
mode.
As soon as the tool is connected up for mains-
powered mode, this mode will have priority and
the battery will not be discharged.
6.2 Compressor compressed air operation
(Fig. 1a, 1b, 2)
• To inflate objects with compressed air, use
the compressed air hose (5).
• Connect the adapter of the compressed air
hose to the object you wish to inflate.
• Depending on what you are inflating, also use
the adapters (7, 8, 9) or other adapters availa-
ble from retail stores.
• The pressure at the compressed air hose will
be displayed in the display (11).
• The unit of the displayed pressure can be se-
lected with the button (15). The pressure can
be displayed in units of [bar], [PSI] or [kPa].
• The button (14) allows the desired pressure
to be reduced.
• The button (16) allows the desired pressure
to be increased.
• To switch on the tool, press the pushbutton
for compressed air mode (18).
• The compressor will then pump until the pre-
set pressure on the display is reached, then it
will switch off.
• Warning! Observe the information supplied
by the tire manufacturer and the vehicle ma-
nufacturer relating to the recommended tire
pressure.
• Warning! This equipment is not calibrated!
For a calibrated measurement value, check
the actual tire pressure using a calibrated me-
ter after you have inflated the tires yourself,
e.g. at a petrol station.
• Just before it is switched off, the pressure
which is shown in the display can be 0.05 –
0.2 bar higher than the preselected pressure,
because of overpressure in the air hose.
• Allow the compressor to cool down for about
5 minutes after every 5 minutes of operation
in order to prevent overheating.
6.3 Low-pressure blower operation
(Fig. 1a, 4)
6.3.1 Defl ating (Fig. 2, 4)
• To draw air out of large-volume objects until
they are empty (e.g. deflating an air mattress,
etc.), connect the air hose (3) to the deflate
connection (13). Use the adapter (21) if ne-
cessary.
• Connect the air hose to the object you want
to deflate.
• Switch on the tool by pressing the pushbutton
for low-pressure mode (12).
• Switch off the equipment once the object has
been sufficiently deflated.
6.3.2 Infl ating (Fig. 2, 4)
Warning! When using the equipment to infl ate
objects, check the information and safety inst-
ructions provided by the manufacturer of these
objects.
• To inflate objects with a large volume (e.g.
inflating an air mattress, etc.), connect the air
hose (3) to the inflate connection (4).
• Connect the air hose to the object you wish to
inflate. Use the adapter (21) if necessary.
• Switch on the tool by pressing the pushbutton
for low-pressure mode (12).
• Switch off the equipment once the object has
been sufficiently inflated.
6.4 LED lamp (19)
To switch the LED lamp on/off , press the pushbut-
ton (20).
The LED lamp (19) can be used only in battery-
powered mode.
Anl_PRESSITO_18_25_Hybrid_SPK13.indb 19Anl_PRESSITO_18_25_Hybrid_SPK13.indb 19 15.12.2022 15:35:2715.12.2022 15:35:27