AMW-150M Pocket Scale
150g x 0.1g
USER’S MANUAL
American Weigh Scales
AMW-150M Users Manual
150 x 0.1g
Thank you for purchasing the AMW-150M Pocket Scale.
Please read all operating instructions carefully before use. This
electronic scale is a precision instrument. With normal care and
proper treatment, it will provide years of reliable service.
Never load the scale with more than the maximum capacity.
Avoid any exposure to extreme heat or cold. Your scale
will work better when operated at normal room temperature.
Always allow the scale to acclimate to surrounding temperature
for at least one hour before use.
Give your scale sufcient warm up time. Usually 30-60
seconds before calibration to give the internal components a
chance to stabilize.
Keep your scale in a clean environment. Dust, dirt, moisture,
vibration, air currents, and a close proximity to other electronic
devices can cause an adverse effect on the reliability and ac-
curacy of your scale.
Handle with care. Gently apply all items to be weighed onto
tray top. Although this scale is designed to be quite durable, try
to avoid rough treatment which can permanently damage the
internal sensor.
Avoid shaking, dropping, or otherwise shocking the scale.
This is a precision instrument and must be handled with ex-
treme care.
Only operate the scale on a stable, vibration free surface.
Operating Instructions:
This scale requires two AAA 1.5V Batteries (included). To
install batteries, ip the scale over and remove the two battery
compartment covers. Place one AAA Battery in each compart-
ment. Replace the battery compartment covers and place on a
FLAT and STABLE surface to start weighing.
Note: DO NOT USE EXCESSIVE FORCE when replacing or
removing the battery covers.
Weighing:
1. Please note: this scale actually has four keys, not two.
2. Before using the scale, allow it to warm up for approximately
10 seconds after turning on.
3. Turn the scale on by pressing the “ON/OFF” key and the
display will show some random characters then “0.0g”.
4. To use the Tare function, place the container you wish to
use on the scale (ex. The protective lid can also be used as a
container). Press the “TARE” key to remove the weight of the
container and reset the scale to zero.
5. To change weighing units between grams (g) or ounces (oz),
press the “G/OZ” key.
6. For an explanation of calibration using the “CAL” key, see
next section.
Calibration procedures:
1. Remove the scale cover and place on a at and stable surface.
(Very important)
2. Turn the scale on and wait until “0.0g” shows on display
3. Press and hold the “CAL” key until the display shows “CAL” and
then “0.0g”. Press the “CAL” key once more and the scale will show
“100.0g”
4. Gently place a 100g weight (not included) onto the tray and wait for
5 seconds. Press the “CAL” key again and the scale will show “PASS”
then “100.0g”
6. Press the “ON/OFF” key to turn the scale off and remove the weight.
Calibration is now complete.
Specications
Weighing Units Grams, Ounces
Capacity 150g x 0.1g
5.3oz x 0.005oz
Calibration Digital User Calibration with 100g
weight
Power 2 “AAA” Batteries
Warranty 10 Year Warranty
Product Dimensions 4” (l) x 2.75 (w) x 0.9” (h)
Tray Dimensions 2.5” x 2.5”
Operating Temp. 50°F - 86°F