Nibe UKV 40 Accumulator Tank Kasutusjuhend

Tüüp
Kasutusjuhend
UKV 40
Användar- och installatörshandbok
- Ackumulatortank
SE
User and Installer Manual – Accumu-
lator tank
GB
Benutzer- und Installateurhandbuch
– Pufferspeicher
DE
Käyttö- ja asennusohje - Varaajasäiliö
FI
Gebruikers- en installatiehandleiding
– Buffervat
NL
Manual de utilizare și instalare –
Rezervor acumulator
RO
Instrukcja obsługi i montażu – zbior-
nik buforowy
PL
CHB 2227-6
031532
Svenska
4Viktig information
6Till användaren
7Till installatören
9Tekniska uppgifter
English
10Important information
12For the User
13For the Installer
15Technical data
Deutsch
16Wichtige Informationen
18Für den Benutzer
19Für den Installateur
21Technische Daten
Suomeksi
22Tärkeää
24Käyttäjälle
25Asentajalle
27Tekniset tiedot
Nederlands
28Belangrijke informatie
30Voor de gebruiker
31Voor de installateur
33Technische gegevens
Romanian
34Informații importante
36Pentru Utilizator
37Pentru instalator
39Date tehnice
Polski
40Ważne informacje
42Dla użytkownika
43Dla instalatora
45Dane techniczne
3UKV 40
Table of Contents
Viktig information
SÄKERHETSINFORMATION
Denna handbok beskriver installations- och servicemoment
avsedda att utföras av fackman.
Handboken ska lämnas kvar hos kunden.
Apparaten får användas av barn över 8
år och av personer med fysisk, sensorisk
eller mental funktionsnedsättning samt
av personer som saknar erfarenhet eller
kunskap under förutsättning att de får
handledning eller instruktioner om hur
man använder apparaten på ett säkert
sätt och informeras så att de förstår
eventuella risker. Barn får inte leka med
apparaten. Låt inte barn rengöra eller
underhålla apparaten utan handledning.
Detta är en originalhandbok. Översättning
får inte ske utan godkännande av NIBE.
Med förbehåll för konstruktionsändringar.
©NIBE 2023.
SYMBOLER
Förklaring till symboler som kan förekomma i denna manual.
OBS!
Denna symbol betyder fara för människa eller ma-
skin.
TÄNK PÅ!
Vid denna symbol finns viktig information om vad
du ska tänka på när du installerar eller servar an-
läggningen.
MÄRKNING
Förklaring till symboler som kan förekomma på produktens
etikett/etiketter.
ALLMÄNT
UKV 40 är konstruerad och tillverkad enligt god teknisk
praxis1för att säkerställa en säker användning.
1Tryckkärlsdirektivet 2014/68/EU Artikel 4 punkt 3.
SERIENUMMER
Serienumret hittar du på toppen av produkten.
TÄNK PÅ!
Uppge alltid produktens serienummer när du gör
en felanmälan.
ÅTERVINNING
Lämna avfallshanteringen av emballaget till den
installatör som installerade produkten eller till sär-
skilda avfallsstationer.
När produkten är uttjänt får den inte slängas bland
vanligt hushållsavfall. Den ska lämnas in till särskilda avfalls-
stationer eller till återförsäljare som tillhandahåller denna
typ av service.
Felaktig avfallshantering av produkten från användarens
sida gör att administrativa påföljder tillämpas i enlighet med
gällande lagstiftning.
LANDSSPECIFIK INFORMATION
Sverige
Garanti- och försäkringsinformation
Det är ägaren som har huvudansvaret för anläggningen.
Om du misstänker att anläggningen på något sätt inte fun-
gerar som den ska anmäler du detta omgående till installa-
tören eller den du köpte produkten av.
Mellan privatperson och företaget som sålt UKV 40 gäller
konsumentlagen. För fullständiga villkor se www.konsument-
verket.se.
Mellan NIBE och det företag som sålt produkten gäller AA
VVS. I enlighet med denna lämnar NIBE tre års produktgaran-
ti till företaget som sålt produkten. Produktgarantin ersätter
inte höjd energiförbrukning eller skada som uppkommit p.g.a.
yttre omständigheter som t.ex. felaktig installation, vatten-
kvalité eller elektriska spänningsvariationer.
UKV 40 | SE4
Svenska
INSTALLATIONSKONTROLL
Enligt gällande regler ska värmeanläggningen undergå installationskontroll innan den tas i bruk. Kontrollen får endast ut-
föras av person som har kompetens för uppgiften.
DatumSignaturAnmärkningBeskrivning
Värmebärare (sida 8)
Avstängningsventiler
Säkerhetsventil
5UKV 40 | SE
Till användaren
TILLSYN OCH SKÖTSEL
Säkerhetsventilen i det system där ackumulatortanken är
installerad ska kontrolleras regelbundet (ca fyra gånger per
år) för att förhindra igensättning.
Kontrollen sker genom att öppna säkerhetsventilen manuellt,
vatten ska då strömma genom spillröret. Skulle så ej ske är
säkerhetsventilen defekt och måste bytas.
SERVICE
Vid behov av service, kontakta installatören. Serienummer
(PZ3) (14 siffror) och installationsdatum ska alltid uppges.
Endast av NIBE levererade reservdelar får användas.
UKV 40 | SE6
Till installatören
ALLMÄNT
UKV 40 kan ha flera olika användningsområde.
UKV 40 kan användas vid extern styrning på värmesystemet.
Värmepumpen laddar då UKV 40 med flytande eller fast
kondensering. Den externa styrningen styr värmedistribu-
tionen från UKV 40 till förbrukaren.
Om flödet till värmesystemet kan strypas t.ex. med radiator-
termostater monteras en UKV 40 som mellantank. Detta
medför ett säkert flöde för värmepumpen.
UKV 40 möjliggör också ett högre flöde till värmesystemet
än över värmepumpen.
I vissa installationer uppstår s.k. värmeknäppningar till följd
av rörelser vid temperaturförändringar. För att eliminera
tillfälliga temperaturförändringar, och därmed undvika vär-
meknäppningar, monteras en UKV 40 efter värmeanläggning-
en.
UKV 40 kan även användas för att öka systemvolymen och
därmed kan driftproblem undvikas.
Ackumulatortanken består av ett kondensisolerat stålkärl
med isolering av polyuretan. Ytterbeklädnad av vit pulverlac-
kerad stålplåt med gavlar av slagtålig plast.
Ackumulatortanken är konstruerad och tillverkad för ett
maximalt avsäkringstryck av 6 bar.
Arbetstemperatur är +4 till +95 °C.
TRANSPORT
UKV 40 ska transporteras och förvaras torrt.
UPPSTÄLLNING
Ackumulatortanken ska installeras i ett torrt utrymme och
med en temperatur som inte understiger 0 °C (frostfritt).
MONTERING
UKV 40 monteras vertikalt hängande på vägg. Sätt först upp
den medlevererade upphängningskonsolen på väggen och
häng därefter upp UKV 40 på konsolen.
BIPACKADE KOMPONENTER
Upphängningskonsol.
KOMPONENTPLACERING
UKV 40
PZ3
UL2
BenämningBeteckning
Hål för väggfästeUL2
SerienummerskyltPZ3
7UKV 40 | SE
INSTALLATION
Samtliga anslutningar (även anslutningar och hål som inte
används) ska isoleras för att minimera tomgångsförlusterna.
DOCKNINGAR
OBS!
Detta är principschemor. Verklig anläggning ska
projekteras enligt gällande normer.
Volymökning samt reducering av
värmeknäppningar
I de fall då systemvolymen i klimatsystemet är under mini-
mum rekommenderad volym för värmepump installeras en
UKV 40 som volymhöjare.
Volym- och flödeshöjare samt reducering av
värmeknäppningar
I de fall då systemvolymen i klimatsystemet är under mini-
mum rekommenderad volym för värmepump och/eller flödet
stryps okontrollerat installeras en UKV 40 som volym- och
flödeshöjare.
Volymökning samt reducering av
värmeknäppningar
I de fall då systemvolymen i klimatsystemet är under mini-
mum rekommenderad volym för värmepump installeras en
UKV 40 som volymhöjare.
RÖRINSTALLATION
Rörinstallation ska utföras enligt gällande regler.
Avtappningsventilen monteras på värmesystemets framled-
ning (XL1).
Systemet där UKV 40 är installerad ska förses med säker-
hetsventilen på högst 6 bar (0,6 MPa).
Spillrörets dimension ska vara samma som säkerhetsventi-
lens. Förlägg spillvattenrör från säkerhetsventilen sluttande
i hela sin längd och se till att det är frostfritt anordnat och
väl stagat. Mynningen på spillröret ska vara synlig och inte
vara placerad i närheten av elektriska komponenter.
Säkerställ att inkommande vatten är rent.
Vid oklarhet kontakta rörinstallatör alternativt se gällande
normer.
PÅFYLLNING
Påfyllning av ackumulatortanken sker genom att:
1. Avlufta ackumulatortanken genom att lossa anslutning
(XL8) i toppen på ackumulatortanken.
2. Fyll på kärlet genom avtappningsventilen.
3. När det endast kommer vatten ur anslutningen (XL8)
(till en början kommer luftblandat vatten) kan anslutning-
en stängas och ackumulatortanken är fylld.
UKV 40 | SE8
Tekniska uppgifter
MÅTT
UKV 40
495
G1” inv
155
Ø450
160
RÖRANSLUTNINGAR
UKV 40
XL8
XL1
RÖRDIMENSIONER
Anslutning
G1" inv.Framledning värmesystemXL1
G1" inv.Dockning från värmepumpXL8
TEKNISKA DATA
UKV 40Modell
39literVolym
16kgNettovikt
0,6 / 6MPa/barMax arbetstryck
+4 - +95°CMax arbetstemperatur
686 19
40
RSK nr
088 470Art. nr
ENERGIMÄRKNING
NIBETillverkare
UKV-40Modell
B
Effektivitetsklass 1
28WVärmeförlust
39lVolym
1Skala för produktens effektivitetsklass A+ till F.
9UKV 40 | SE
Important information
SAFETY INFORMATION
This manual describes installation and service procedures
for implementation by specialists.
The manual must be left with the customer.
This appliance can be used by children
aged from 8 years and above and per-
sons with reduced physical, sensory or
mental capabilities or lack of experience
and knowledge if they have been given
supervision or instruction concerning use
of the appliance in a safe way and under-
stand the hazards involved. Children shall
not play with the appliance. Cleaning and
user maintenance shall not be made by
children without supervision.
This is an original manual. It may not be
translated without the approval of NIBE.
Rights to make any design or technical
modifications are reserved.
©NIBE 2023.
SYMBOLS
Explanation of symbols that may be present in this manual.
NOTE
This symbol indicates danger to person or machine.
Caution
This symbol indicates important information about
what you should consider when installing or servi-
cing the installation.
MARKING
Explanation of symbols that may be present on the product’s
label(s).
GENERAL
UKV 40 is designed and manufactured according sound
engineering practice1in order to ensure safe usage.
1Pressure Equipment Directive 2014/68/EU Article 4 point 3.
SERIAL NUMBER
The serial number can be found on top of the product.
Caution
Always give the product's serial number when re-
porting a fault.
RECOVERY
Leave the disposal of the packaging to the installer
who installed the product or to special waste sta-
tions.
Do not dispose of used products with normal
household waste. It must be disposed of at a special waste
station or dealer who provides this type of service.
Improper disposal of the product by the user results in ad-
ministrative penalties in accordance with current legislation.
UKV 40 | EN10
English
INSPECTION OF THE INSTALLATION
Current regulations require the heating installation to be inspected before it is commissioned. The inspection must be
carried out by a suitably qualified person.
DateSignatureNotesDescription
Heating medium (page 14)
Shut off valves
Safety valve
11UKV 40 | EN
For the User
MAINTENANCE
The safety valve in the system where the accumulator tank
is installed must be inspected regularly (about four times a
year) to prevent blockages.
To inspect the valve, open the safety valve manually and
check that water flows through the overflow pipe. If this
does not happen then the safety valve is defective and must
be replaced.
SERVICE
For service, contact the installer. Serial number (PZ3) (14
digits) and installation date should always be stated.
Only replacement parts supplied by NIBE may be used.
UKV 40 | EN12
For the Installer
GENERAL
UKV 40 has several different areas of use.
UKV 40 can be used during external control of the heating
system. The heat pump then charges UKV 40 with floating
or fixed condensing. The external control function controls
the heat distribution from UKV 40 to the consumer.
If the flow to the heating system can be restricted using
radiator thermostats, for example, install a UKV 40 as an
intermediate tank. This ensures a secure flow for the heat
pump.
UKV 40 also allows a greater flow to the heating system
than across the heat pump.
In some installations, so-called heating clicks occur as a
result of movements during changes in temperature. To
eliminate temporary changes in temperature, and thereby
prevent heating clicks, install a UKV 40 after the heating
installation.
UKV 40 can also be used to increase the system volume and
thereby prevent malfunctions.
The accumulator tank consists of a condensation-insulated
steel vessel with polyurethane insulation. Outer cladding in
white, powder-coated sheet metal with ends of durable
plastic.
The accumulator tank is designed and manufactured for a
maximum cut-off pressure of 6 bar.
The working temperature is +4 to +95 °C.
TRANSPORT
UKV 40 should be transported and stored in the dry.
ASSEMBLY
The accumulator tank must be installed in a dry area at a
temperature that does not drop below 0 °C (frost-free).
MOUNTING
UKV 40 has to be installed vertically suspended on the wall.
First install the enclosed mounting bracket on the wall, then
suspend UKV 40 from the bracket.
SUPPLIED COMPONENTS
Suspension bracket.
COMPONENT LOCATION
UKV 40
PZ3
UL2
NameDesigna-
tion
Holes for wall bracketUL2
Serial number platePZ3
13UKV 40 | EN
INSTALLATION
All connections (including connections or holes that are not
used) must be insulated to minimise energy losses.
DOCKINGS
NOTE
These are outline diagrams. Actual installations
must be planned according to applicable stand-
ards.
Volume increase as well as reduction of heat
spikes
A UKV 40 is installed as a volume increaser in those cases
where the system volume in the climate system is below
the minimum recommended volume for the heat pump.
Volume and flow increaser and reduction in
heat spikes
A UKV 40 is installed as a volume and flow increaser in those
cases where the system volume in the climate system is
below the minimum recommended volume for the heat pump
and/or the flow is restricted without control.
Volume increase as well as reduction of heat
spikes
A UKV 40 is installed as a volume increaser in those cases
where the system volume in the climate system is below
the minimum recommended volume for the heat pump.
PIPE INSTALLATION
Pipe installation must be carried out in accordance with
current norms and directives.
The drain valve is installed on the heating system’s supply
line (XL1).
The system where UKV 40 is installed must be supplied with
a safety valve of max. 6 bar (0.6 MPa).
The overflow pipe must be the same size as the safety
valve's. Route the overflow pipe from the safety valve,
sloping along its entire length, and ensure that it is frost-
proof and well supported. The mouth of the overflow pipe
must be visible and not placed close to electrical compon-
ents.
Ensure that incoming water is clean.
If uncertain, contact a plumber alternatively see applicable
standards.
FILLING
Fill the accumulator tank as follows:
1. Vent the accumulator tank by loosening the connection
(XL8) at the top of the accumulator tank.
2. Fill the vessel through the drain valve.
3. When only water comes out of the connection (XL8) (an
air-water mixture emerges initially), the connection can
be closed and the accumulator tank is filled.
UKV 40 | EN14
Technical data
DIMENSIONS
UKV 40
495
G1” inv
155
Ø450
160
PIPE CONNECTIONS
UKV 40
XL8
XL1
PIPE DIMENSIONS
Connection
G1" int.Supply line, heating systemXL1
G1" int.Docking from heat pumpXL8
TECHNICAL SPECIFICATIONS
UKV 40Model
39litreVolume
16kgNet weight
0.6 / 6MPa/barMax. operating pressure
+4 - +95°CMax. operating temperature
088 470Part No.
ENERGY LABELLING
NIBESupplier
UKV-40Model
B
Efficiency class 1
28WHeat loss
39lVolume
1Scale for the product’s efficiency class A+ to F.
15UKV 40 | EN
Wichtige Informationen
SICHERHEITSINFORMATIONEN
In diesem Handbuch werden Installations- und Servicevor-
gänge beschrieben, die von Fachpersonal auszuführen sind.
Dieses Handbuch verbleibt beim Kunden.
Dieses Gerät darf von Kindern ab einem
Alter von 8 Jahren sowie von Personen
mit eingeschränkten physischen, senso-
rischen oder geistigen Fähigkeiten oder
mangelnden Erfahrungen und Wissen nur
dann verwendet werden, wenn diese
unter Aufsicht stehen oder eine Anlei-
tung zur sicheren Benutzung des Geräts
erhalten haben und sich der vorhande-
nen Risiken bewusst sind. Kinder dürfen
nicht mit dem Gerät spielen. Eine Reini-
gung und Wartung durch den Benutzer
darf nicht von Kindern ohne Aufsicht
ausgeführt werden.
Dies ist ein Originalhandbuch. Eine Über-
setzung darf nur nach Genehmigung
durch NIBE stattfinden
Technische Änderungen vorbehalten!
©NIBE 2023.
SYMBOLE
Erklärung der Symbole, die in diesem Handbuch abgebildet
sein können.
HINWEIS!
Dieses Symbol kennzeichnet eine Gefahr für Per-
sonen und Maschinen.
ACHTUNG!
Dieses Symbol verweist auf wichtige Angaben
dazu, was bei Installation oder Wartung der Anlage
zu beachten ist.
KENNZEICHNUNG
Erklärung der Symbole, die auf den Produktetiketten abge-
bildet sein können.
ALLGEMEINES
UKV 40 ist gemäß guter Ingenieurpraxis1konstruiert und
hergestellt, um eine sichere Nutzung zu gewährleisten.
1Druckgeräterichtlinie 2014/68/EU Artikel 4 Punkt 3.
SERIENNUMMER
Die Seriennummer wird auf der Produktoberseite angegeben.
ACHTUNG!
Geben Sie stets die Seriennummer des Produkts
an, wenn Sie einen Fehler melden.
RECYCLING
Übergeben Sie den Verpackungsabfall dem Installa-
teur, der das Produkt installiert hat, oder bringen
Sie ihn zu den entsprechenden Abfallstationen.
Wenn das Produkt das Ende seiner Lebensdauer
erreicht hat, darf es nicht über den normalen Hausmüll
entsorgt werden. Stattdessen muss es bei speziellen Entsor-
gungseinrichtungen oder Händlern abgegeben werden, die
diese Dienstleistung anbieten.
Eine unsachgemäße Entsorgung des Produkts durch den
Benutzer zieht Verwaltungsstrafen gemäß geltendem Recht
nach sich.
UKV 40 | DE16
Deutsch
INSTALLATIONSKONTROLLE
Die Heizungsanlage ist vor der Inbetriebnahme einer Installationskontrolle gemäß den geltenden Vorschriften zu unterziehen.
Diese Kontrolle darf nur von sachkundigen Personen ausgeführt werden.
DatumUnter-
schrift
AnmerkungBeschreibung
Heizungsmedium (Seite 20)
Absperrventile
Sicherheitsventil
17UKV 40 | DE
Für den Benutzer
KONTROLLE UND WARTUNG
Das Sicherheitsventil in dem System, in dem der Speicher-
tank installiert ist, muss regelmäßig kontrolliert werden (ca.
viermal pro Jahr), um Blockierungen zu verhindern.
Bei der Kontrolle wird das Sicherheitsventil per Hand geöff-
net. Dabei sollte Wasser durch das Überlaufrohr fließen.
Andernfalls ist das Sicherheitsventil defekt und muss ersetzt
werden.
SERVICE
Wenden Sie sich bei Servicebedarf an den Installateur. Seri-
ennummer (PZ3; 14 Ziffern) und Installationsdatum sind
stets anzugeben.
Es dürfen nur Ersatzteile verwendet werden, die von NIBE
geliefert wurden.
UKV 40 | DE18
Für den Installateur
ALLGEMEINES
Für UKV 40 existieren unterschiedliche Einsatzmöglichkei-
ten.
UKV 40 lässt sich bei der externen Steuerung des Heizsys-
tems einsetzen. Die Wärmepumpe lädt in diesem Fall UKV 40
mit gleitender oder fester Kondensierung. Die externe
Steuerung regelt die Wärmeverteilung von UKV 40 zum
Verbraucher.
Wenn der Volumenstrom zum Heizsystem gedrosselt werden
kann (z. B. mit Heizkörperthermostaten), wird ein UKV 40
als Pufferspeicher montiert. Dies bewirkt einen sicheren
Volumenstrom für die Wärmepumpe.
UKV 40 ermöglicht zudem einen höheren Volumenstrom
zum Heizsystem als über die Wärmepumpe.
Bei bestimmten Installationen entstehen Knackgeräusche,
die auf Bewegungen bei Temperaturänderungen beruhen.
Um vorübergehende Temperaturänderungen und damit
Knackgeräusche durch Wärmeänderungen auszuschließen,
wird eine UKV 40-Einheit im Anschluss an die Heizungsan-
lage montiert.
Mit UKV 40 kann darüber hinaus das Systemvolumen gestei-
gert werden, um Betriebsstörungen zu verhindern.
Der Pufferspeicher besteht aus einem gegen Kondensation
isolierten Stahlgefäß mit einer Isolierung aus Polyurethan.
Die Außenverkleidung ist aus weißem, pulverbeschichtetem
Stahlblech mit Stirnseiten aus schlagfestem Kunststoff ge-
fertigt.
Der Speichertank wird für einen maximalen Absicherungs-
druck von 6 Bar konstruiert und hergestellt.
Die Arbeitstemperatur beträgt +4 bis +95 °C.
TRANSPORT
UKV 40 muss trocken transportiert und gelagert werden.
AUFSTELLUNG
Der Pufferspeicher muss in einem trockenen Raum mit einer
Temperatur, die 0 °C nicht unterschreiten darf (frostfrei),
installiert werden.
MONTAGE
UKV 40 wird vertikal an der Wand hängend montiert. Bringen
Sie zunächst die mitgelieferte Aufhängekonsole an der Wand
an und hängen Sie dann UKV 40 an der Konsole auf.
BEILIEGENDE KOMPONENTEN
Aufhängekonsole.
POSITION DER KOMPONENTEN
UKV 40
PZ3
UL2
BezeichnungBezeich-
nung
Öffnung für WandhalterungUL2
SeriennummernschildPZ3
19UKV 40 | DE
INSTALLATION
Alle Anschlüsse (auch nicht verwendete Anschlüsse und
Öffnungen) müssen isoliert werden, um Leerlaufverluste zu
minimieren.
ANSCHLUSSOPTIONEN
HINWEIS!
Dies sind Prinzipskizzen. Die tatsächliche Anlage
muss gemäß den geltenden Normen geplant und
montiert werden.
Volumenerhöhung und Reduzierung von
Knackgeräuschen durch Wärmeänderungen
Wenn das Systemvolumen im Klimatisierungssystem unter
dem empfohlenen Mindestvolumen für die Wärmepumpe
liegt, ist ein UKV 40 zur Volumenstromvergrößerung zu in-
stallieren.
Volumen-undDurchflussvergrößerungsowie
Reduzierung von Knackgeräuschen durch
Temperaturänderungen
Wenn das Systemvolumen im Klimatisierungssystem unter
dem empfohlenen Mindestvolumen für die Wärmepumpe
liegt bzw. der Volumenstrom unkontrolliert gedrosselt wird,
ist ein UKV 40 zur Volumen- und Durchflussvergrößerung
zu installieren.
Volumenerhöhung und Reduzierung von
Knackgeräuschen durch Wärmeänderungen
Wenn das Systemvolumen im Klimatisierungssystem unter
dem empfohlenen Mindestvolumen für die Wärmepumpe
liegt, ist ein UKV 40 zur Volumenstromvergrößerung zu in-
stallieren.
ROHRINSTALLATION
Die Rohrinstallation muss gemäß den geltenden Vorschriften
ausgeführt werden.
Das Entleerungsventil wird am Vorlauf des Heizsystems
montiert (XL1).
Das System, in dem UKV 40 installiert ist, muss mit einem
Sicherheitsventil mit maximal 6 bar (0,6 MPa) bestückt
werden.
Die Abmessungen des Überlaufrohrs müssen mit denen des
Sicherheitsventils übereinstimmen. Das Überlaufrohr vom
Sicherheitsventil muss über die gesamte Länge mit Gefälle
verlegt werden. Darauf achten, dass die Anlage frostfrei und
gut ausgesteift verlegt wird. Der Austritt des Überlaufrohrs
muss im Sichtbereich liegen und darf sich nicht in der Nähe
elektrischer Komponenten befinden.
Stellen Sie sicher, dass das einströmende Wasser sauber ist.
Wenden Sie sich im Zweifelsfall an den Klempner bzw. kon-
sultieren Sie die geltenden Normen.
BEFÜLLUNG
Der Brauchwasserspeicher wird wie folgt befüllt:
1. Entlüften Sie den Pufferspeicher, indem Sie den An-
schluss (XL8) an der Oberseite des Pufferspeichers lö-
sen.
2. Befüllen Sie den Behälter durch das Entleerungsventil.
3. Wenn nur noch Wasser aus dem Anschluss austritt (XL8)
(dieses enthält zunächst Lufteinschlüsse), kann der
Anschluss geschlossen werden und der Pufferspeicher
gilt als befüllt.
UKV 40 | DE20
  • Page 1 1
  • Page 2 2
  • Page 3 3
  • Page 4 4
  • Page 5 5
  • Page 6 6
  • Page 7 7
  • Page 8 8
  • Page 9 9
  • Page 10 10
  • Page 11 11
  • Page 12 12
  • Page 13 13
  • Page 14 14
  • Page 15 15
  • Page 16 16
  • Page 17 17
  • Page 18 18
  • Page 19 19
  • Page 20 20
  • Page 21 21
  • Page 22 22
  • Page 23 23
  • Page 24 24
  • Page 25 25
  • Page 26 26
  • Page 27 27
  • Page 28 28
  • Page 29 29
  • Page 30 30
  • Page 31 31
  • Page 32 32
  • Page 33 33
  • Page 34 34
  • Page 35 35
  • Page 36 36
  • Page 37 37
  • Page 38 38
  • Page 39 39
  • Page 40 40
  • Page 41 41
  • Page 42 42
  • Page 43 43
  • Page 44 44
  • Page 45 45
  • Page 46 46
  • Page 47 47
  • Page 48 48

Nibe UKV 40 Accumulator Tank Kasutusjuhend

Tüüp
Kasutusjuhend